Ohio Admin. Code 3701:1-48-23 - Record keeping requirements
(A) Each licensee shall maintain a copy of
its license, license conditions, documents incorporated by reference, and
amendments to each of these items until superseded by new documents approved by
the director, or until the director terminates the license.
(B) Each licensee shall maintain records
showing the receipts and transfers of all sealed sources and all devices using
depleted uranium for shielding and retain each record for three years after it
is made. These records must include the date, the name of the individual making
the record, radionuclide, number of becquerels (curies) or mass (for depleted
uranium), and manufacturer, model, and serial number of each sealed source
and/or device, as appropriate.
(C)
Each licensee shall maintain records of the calibrations of its radiation
survey instruments that are required under rule
3701:1-48-08 of the
Administrative Code and retain each record for three years after it is
made.
(D) Each licensee shall
maintain records of leak test results for sealed sources and also for devices
containing depleted uranium. The results must be stated in units of becquerels
(microcuries). The licensee shall retain each record for three years after it
is made or until the source in storage is removed from storage.
(E) Each licensee shall maintain records of
the quarterly inventory of sealed sources and of devices containing depleted
uranium as required by rule
3701:1-48-10 of the
Administrative Code and retain each record for three years after it is made.
The record must include the date of the inventory, name of the individual
conducting the inventory, radionuclide, number of becquerels (curies) or mass
(for depleted uranium) in each device, location of sealed source and/or
devices, and manufacturer, model, and serial number of each sealed source
and/or device, as appropriate.
(F)
(1) Each licensee shall maintain utilization
logs showing for each sealed source the following information:
(a) A description, including the make, model,
and serial number of the radiographic exposure device or transport or storage
container in which the sealed source is located;
(b) The identity and signature of the
radiographer to whom assigned; and
(c) The plant or site where used and dates of
use, including the dates removed and returned to storage.
(2) The licensee shall retain the logs
required by paragraph (F)(1) of this rule for three years after the log is
made.
(G) Each licensee
shall maintain records specified in rule
3701:1-48-11 of the
Administrative Code of equipment problems found in daily checks and quarterly
inspections of radiographic exposure devices, transport and storage containers,
associated equipment, source changers, and survey instruments; and retain each
record for three years after it is made. The record must include the date of
check or inspection, name of inspector, equipment involved, any problems found,
and what repair and/or maintenance, if any, was done.
(H) Each licensee shall maintain records of
alarm system and entrance control device tests required under rule
3701:1-48-12 of the
Administrative Code and retain each record for three years after it is
made.
(I) Each licensee shall
maintain the following records of training and certification for three years
after the record is made:
(1) Records of
training of each radiographer and each radiographer's assistant. The record
must include radiographer certification documents and verification of
certification status, copies of written tests, dates of oral and practical
examinations, and names of individuals conducting and receiving the oral and
practical examinations; and
(2)
Records of annual refresher safety training and semi-annual inspections of job
performance for each radiographer and each radiographer's assistant. The
records must list the topics discussed during the refresher safety training,
the dates the annual refresher safety training was conducted, and names of the
instructors and attendees. For inspections of job performance, the records must
also include a list showing the items checked and any items of noncompliance
observed by the radiation safety officer for industrial radiography.
(J) Each licensee shall maintain a
copy of current operating and emergency procedures until the director
terminates the license. Superseded material must be retained for three years
after the change is made.
(K) Each
licensee shall maintain the following exposure records specified in rule
3701:1-48-19 of the
Administrative Code:
(1) Direct reading
dosimeter readings and yearly operability checks required by paragraphs (B) and
(C) of rule
3701:1-48-19 of the
Administrative Code for three years after the record is made.
(2) Records of alarm rate meter calibrations
for three years after the record is made.
(3) Personnel dosimeter results
received from an accredited national voluntary
laboratory accreditation program (NVLAP) processor until the director
terminates the license.
(4) Records
of estimates of exposures as a result of off-scale personal direct reading
dosimeters, or lost, or damaged personnel dosimeters until the director
terminates the license.
(L) Each licensee shall maintain a record of
each exposure device survey conducted before the device is placed in storage as
specified in paragraph (C) of rule
3701:1-48-20 of the
Administrative Code, if that survey is the last one performed in the workday.
Each record must be maintained for three years after it is made.
(M) Each record required by this part must be
legible throughout the specified retention period. The record may be the
original or a reproduced copy or a microform provided that the copy or
microform is authenticated by authorized personnel and that the microform is
capable of reproducing a clear copy throughout the required retention period.
The record may also be stored in electronic media with the capability for
producing legible, accurate, and complete records during the required retention
period. Records, such as letters, drawings, and specifications, must include
all pertinent information, such as stamps, initials, and signatures. The
licensee shall maintain adequate safeguards against tampering with and loss of
records.
(N)
(1) Each licensee shall maintain copies of
records required by this and other chapters at the location specified in
paragraph (K) of rule
3701:1-48-04 of the
Administrative Code.
(2) Each
licensee shall also maintain copies of the following documents and records
sufficient to demonstrate compliance at each applicable field station and each
temporary job site:
(a) The license
authorizing the use of licensed material;
(b) A copy of Chapters 3701:1-38 and
3701:1-48 of the Administrative Code;
(c) Utilization records for each radiographic
exposure device dispatched from that location as required by paragraph (F) of
this rule;
(d) Records of equipment
problems identified in daily checks of equipment as required by paragraph (G)
of this rule;
(e) Records of alarm
system and entrance control checks required by paragraph (H) of this rule, if
applicable;
(f) Records of direct
reading dosimeters such as pocket dosimeter and/or electronic personal
dosimeters readings as required by paragraph (K) of this rule;
(g) Operating and emergency procedures
required by paragraph (J) of this rule;
(h) Evidence of the latest calibration of the
radiation survey instruments in use at the site, as required by paragraph (C)
of this rule;
(i) Evidence of the
latest calibrations of alarm rate meters and operability checks of pocket
dosimeters and/or electronic personal dosimeters as required by paragraph (K)
of this rule;
(j) Latest survey
records required by paragraph (L) of this rule;
(k) The shipping papers for the
transportation of radioactive materials required by rule
3701:1-50-05 of the
Administrative Code; and
(l) When
operating under reciprocity, a copy of the agreement state or United States
nuclear regulatory commission license authorizing the use of licensed
materials.
Notes
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.06, 3748.07
Prior Effective Dates: 10/20/2002, 03/22/2007, 01/01/2012
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.