As used in rules
3745-51-780 to
3745-51-789 of the
Administrative Code, all terms not defined herein have the meaning given in the
Resource Conservation and Recovery Act and Chapters 3745-50 to 3745-57, 3745-65
to 3745-69, 3745-205, 3745-256, and 3745-266 of the Administrative
Code.
(A)
"Average volatile organic (VO) concentration" or
"average VO concentration" means the mass-weighted average volatile organic
concentration of a hazardous secondary material as determined in accordance
with the requirements of rule
3745-51-784 of the
Administrative Code.
(B)
[Reserved.]
(C)
(1)
"Closure device" means a cap, hatch, lid, plug, seal,
valve, or other type of fitting that blocks an opening in a cover such that
when the device is secured in the closed position the closure device prevents
or reduces air pollutant emissions to the atmosphere. Closure devices include
devices that are detachable from the cover (e.g., a sampling port cap),
manually operated (e.g., a hinged access lid or hatch), or automatically
operated (e.g., a spring-loaded pressure relief valve).
(2)
"Continuous seal"
means a seal that forms a continuous closure that completely covers the space
between the edge of the floating roof and the wall of a tank. A continuous seal
may be a vapor-mounted seal, liquid-mounted seal, or metallic shoe seal. A
continuous seal may be constructed of fastened segments so as to form a
continuous seal.
(3)
"Cover" means a device that provides a continuous
barrier over the hazardous secondary material managed in a unit to prevent or
reduce air pollutant emissions to the atmosphere. A cover may have openings
(such as access hatches, sampling ports, gauge wells) that are necessary for
operation, inspection, maintenance, and repair of the unit on which the cover
is used. A cover may be a separate piece of equipment which can be detached and
removed from the unit or a cover may be formed by structural features
permanently integrated into the design of the unit.
(D)
[Reserved.]
(E)
(1)
"Empty hazardous secondary material container"
means:
(a)
A
container from which all hazardous secondary materials have been removed that
can be removed using the practices commonly employed to remove materials from
that type of container, e.g., pouring, pumping, and aspirating, and no more
than 2.5 centimeters (one inch) of residue remain on the bottom of the
container or inner liner;
(b)
A container that is less than or equal to one
hundred-nineteen gallons in size and no more than three per cent by weight of
the total capacity of the container remains in the container or inner liner;
or
(c)
A container that is greater than one hundred-nineteen
gallons in size and no more than 0.3 per cent by weight of the total capacity
of the container remains in the container or inner liner.
(2)
"Enclosure" means a structure that surrounds a tank or
container, captures organic vapors emitted from the tank or container, and
vents the captured vapors through a closed-vent system to a control
device.
(3)
"External floating roof" means a pontoon-type or
double-deck type cover that rests on the surface of the material managed in a
tank with no fixed roof.
(F)
(1)
"Fixed roof" means a cover that is mounted on a unit in
a stationary position and does not move with fluctuations in the level of the
material managed in the unit.
(2)
"Floating
membrane" cover means a cover consisting of a synthetic flexible membrane
material that rests upon and is supported by the hazardous secondary material
being managed in a surface impoundment.
(3)
"Floating roof"
means a cover consisting of a double deck, pontoon single deck, or internal
floating cover which rests upon and is supported by the material being
contained, and is equipped with a continuous seal.
(G)
[Reserved.]
(H)
"Hard-piping"
means pipe or tubing that is manufactured and properly installed in accordance
with relevant standards and good engineering practices.
(I)
(1)
"In light material service" means the container is used
to manage a material for which vapor pressure of one or more of the organic
constituents in the material is greater than 0.3 kilopascals (kPa) at twenty
degrees Celsius, and the total concentration of the pure organic constituents
having a vapor pressure greater than 0.3 kPa at twenty degrees Celsius is equal
to or greater than twenty per cent by weight.
(2)
"Internal
floating roof" means a cover that rests or floats on the material surface (but
not necessarily in complete contact with the material surface) inside a tank
that has a fixed roof.
(J)
[Reserved.]
(K)
[Reserved.]
(L)
"Liquid-mounted
seal" means a foam or liquid-filled primary seal mounted in contact with the
hazardous secondary material between the tank wall and the floating roof
continuously around the circumference of the tank.
(M)
(1)
"Malfunction" means any sudden, infrequent, and not
reasonably preventable failure of air pollution control equipment, process
equipment, or a process to operate in a normal or usual manner. Failures that
are caused in part by poor maintenance or careless operation are not
malfunctions.
(2)
"Material determination" means performing all
applicable procedures in accordance with the requirements of rule
3745-51-784 of the
Administrative Code to determine whether a hazardous secondary material meets
standards specified in rules
3745-51-780 to
3745-51-789 of the
Administrative Code. Examples of a material determination include performing
the procedures in accordance with the requirements of rule
3745-51-784 of the
Administrative Code to determine the average VO concentration of a hazardous
secondary material at the point of material origination; the average VO
concentration of a hazardous secondary material at the point of material
treatment and comparing the results to the exit concentration limit specified
for the process used to treat the hazardous secondary material; the organic
reduction efficiency and the organic biodegradation efficiency for a biological
process used to treat a hazardous secondary material and comparing the results
to the applicable standards; or the maximum volatile organic vapor pressure for
a hazardous secondary material in a tank and comparing the results to the
applicable standards.
(3)
"Maximum organic vapor pressure" means the sum of the
individual organic constituent partial pressures exerted by the material
contained in a tank, at the maximum vapor pressure-causing conditions (i.e.,
temperature, agitation, pH effects of combining materials, etc.) reasonably
expected to occur in the tank. For the purpose of rules
3745-51-780 to
3745-51-789 of the
Administrative Code, maximum organic vapor pressure is determined using the
procedures specified in paragraph (C) of rule
3745-51-784 of the
Administrative Code.
(4)
"Metallic shoe seal" means a continuous seal that is
constructed of metal sheets which are held vertically against the wall of the
tank by springs, weighted levers, or other mechanisms and is connected to the
floating roof by braces or other means. A flexible coated fabric (envelope)
spans the annular space between the metal sheet and the floating
roof.
(N)
"No detectable organic emissions" means no escape of
organics to the atmosphere as determined using the procedure specified in
paragraph (D) of rule
3745-51-784 of the
Administrative Code.
(O)
[Reserved.]
(P)
"Point of
material origination" means as follows:
(1)
When the
remanufacturer or other person who stores or treats the hazardous secondary
material is the generator of the hazardous secondary material, the point of
material origination means the point where a material produced by a system,
process, or material management unit is determined to be a hazardous secondary
material excluded under paragraph (A)(27) of rule
3745-51-04 of the Administrative
Code.
[Comment: In this case, this term is
being used in a manner similar to the use of the term "point of generation" in
air standards established under authority of the Clean Air Act in 40 CFR Part
60, Part 61, and Part 63.]
(2)
When the
remanufacturer or other person who stores or treats the hazardous secondary
material is not the generator of the hazardous secondary material, point of
material origination means the point where the remanufacturer or other person
who stores or treats the hazardous secondary material accepts delivery or takes
possession of the hazardous secondary material.
(Q)
[Reserved.]
(R)
[Reserved.]
(S)
(1)
"Safety device" means a closure device such as a
pressure relief valve, frangible disc, fusible plug, or any other type of
device which functions exclusively to prevent physical damage or permanent
deformation to a unit or the unit's air emission control equipment by venting
gases or vapors directly to the atmosphere during unsafe conditions resulting
from an unplanned, accidental, or emergency event. For the purpose of rules
3745-51-780 to
3745-51-789 of the
Administrative Code, a safety device is not used for routine venting of gases
or vapors from the vapor headspace underneath a cover such as during filling of
the unit or to adjust the pressure in this vapor headspace in response to
normal daily diurnal ambient temperature fluctuations. A safety device is
designed to remain in a closed position during normal operations and open only
when the internal pressure, or another relevant parameter, exceeds the device
threshold setting applicable to the air emission control equipment as
determined by the remanufacturer or other person who stores or treats the
hazardous secondary material based on manufacturer recommendations, applicable
regulations, fire protection and prevention codes, standard engineering codes
and practices, or other requirements for the safe handling of flammable,
ignitable, explosive, reactive, or hazardous materials.
(2)
"Single-seal
system" means a floating roof having one continuous seal. This seal may be
vapor-mounted, liquid-mounted, or a metallic shoe seal.
(T)
[Reserved.]
(U)
[Reserved.]
(V)
(1)
"Vapor-mounted seal" means a continuous seal that is
mounted such that there is a vapor space between the hazardous secondary
material in the unit and the bottom of the seal.
(2)
"Volatile organic
concentration" or "VO concentration" means the fraction by weight of the
volatile organic compounds contained in a hazardous secondary material
expressed in terms of parts per million by weight (ppmw) as determined by
direct measurement or by knowledge of the material in accordance with the
requirements of rule
3745-51-784 of the
Administrative Code.
[Comment: For dates of non-regulatory
government publications, publications of recognized organizations and
associations, federal rules, and federal statutory provisions referenced in
this rule, see rule
3745-50-11 of the Administrative
Code titled "Incorporated by reference."]