Okla. Admin. Code § 252:410-15-2 - Controls and security

(a) Area controls. Permanent x-ray industrial radiographic installations shall have high radiation area entrance controls as described in 10 CFR 34.33.
(b) Temporary job sites. At temporary job sites, a radiographer must maintain surveillance over the radiation area during each operation to ensure no one enters the area when radiation is being produced.
(1) Barriers. Ropes and/or barriers should be used when practical to help prevent entry. During pipeline industrial radiographic operations radiation signs and barriers must be positioned in a manner to prevent individuals from entering the area when radiation is being produced.
(2) Posting of radiation areas. Before beginning an industrial radiography operation at a temporary job site, a permittee must identify and post the radiation areas and high radiation areas, or designate a single restricted area based on the exposure limits established in 10 CFR 20.1301 for members of the public. If only a single area is designated, both signs must be posted at the area boundary.
(c) System security. The control panel of each system shall be equipped with a locking device that prevents unauthorized use of the system or accidental production of radiation. This control panel must be kept locked and the key stored in a separate secure location except when a radiographer or assistant radiographer has the system under direct visual surveillance.
(d) Labeling. X-ray tube housings and control boxes must be labeled according to 252:410-13-2(a).

Notes

Okla. Admin. Code § 252:410-15-2
Added at 17 Ok Reg 1136, eff 6-1-00; Amended at 21 Ok Reg 1551, eff 6-11-04

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.