Or. Admin. Code § 437-004-0360 - Fixed Ladders
(1)
Definitions. Fixed ladder terms mean:
(a)
Cage. A guard sometimes referred to as a basket guard that is an enclosure
fastened to the side rails of a fixed ladder or to a structure to encircle the
climbing space of the ladder.
(b)
Cleats. Ladder cross-pieces of rectangular cross-section placed on edge on
which a person may step when climbing up or down.
(c) Fastenings. A device to attach a ladder
to a structure, building, or equipment.
(d) Fixed ladder. A ladder permanently
attached to a structure, building, or equipment.
(e) Grab bars. Individual handholds adjacent
to or as an extension above ladders to provide access beyond the limits of the
ladder.
(f) Individual-rung ladder.
A fixed ladder with each rung individually attached to a structure, building,
or equipment.
(g) Ladder. A device
with steps, rungs or cleats between rails, for people to climb up or
down.
(h) Ladder safety device. Any
device, other than a cage or well, designed to eliminate or reduce the
possibility of accidental falls, that may use life belts, friction brakes, and
sliding attachments.
(i) Pitch. The
included angle between the horizontal and the ladder, measured on the opposite
side of the ladder from the climbing side.
(j) Rail ladder. A fixed ladder with side
rails joined at regular intervals by rungs or cleats and fastened in full
length or in sections to a building, structure, or equipment.
(k) Railings. Any one or a combination of
those railings made according to OAR
437-004-0320. A standard railing
is a vertical barrier along exposed edges of walking surfaces to prevent people
from falling.
(l) Rungs. Ladder
cross-pieces of circular or oval cross-section on which a person may step when
climbing up or down.
(m) Side-step
ladder. One from which a person getting off at the top must step sideways to
reach the landing.
(n) Steps. The
flat cross-pieces of a ladder on which a person may step when climbing up or
down.
(o) Through ladder. A ladder
from which a person getting off at the top must step through to reach the
landing.
(p) Well. A permanent
complete enclosure around a fixed ladder, that is attached to the walls of the
well. Proper clearances for a well will give the climber the same protection as
a cage.
(2) Design
requirements. Design considerations: All ladders, appurtenances, and fastenings
must meet these load requirements:
(a) The
minimum design live load must be a single concentrated load of 200
pounds.
(b) Design consideration
must include the number and position of additional concentrated live load units
of 200 pounds each as determined from anticipated use.
(c) Consider the live loads caused by persons
on the ladder to be concentrated at such points as will cause the maximum
stress in the structural member being under evaluation.
(d) Use the weight of the ladder and
attachments together with the live load when designing rails and
fastenings.
(e) All wood parts of
fixed ladders must meet the requirements of OAR
437-004-0340(3).
(f) For fixed ladders with wood side rails
and wood rungs or cleats, used at an angle between 75° and 90°, and
intended for use by no more than one person per section, single ladders in OAR
437-004-0340(8)(b)(A)
are acceptable.
(3) Specific features.
(a) Rungs and cleats.
(A) All rungs must have a minimum diameter of
3/4 inch for metal ladders, except as in paragraph OAR
437-004-0360(3)(g)(A)
and a minimum diameter of 1-1/8 inches for wood ladders.
(B) The distance between rungs, cleats, and
steps must be uniform and not more than 12 inches.
(C) The minimum clear length of rungs or
cleats must be 16 inches.
(D)
Rungs, cleats, and steps must not have splinters, sharp edges, burrs, or
projections.
(E) The rungs of an
individual rung ladder must not allow the climber's foot to slide off the end.
Figure 2 shows a suggested design. [Figure not included. See ED.
NOTE.]
(b) Side rails.
Side rails that might be used as a climbing aid must be of such cross sections
as to afford adequate gripping surface without sharp edges, splinters, or
burrs.
(c) Fastenings. Fastenings
must be an integral part of fixed ladder design.
(d) Splices. All splices must meet design
requirements noted in (a) above. All splices and connections must have smooth
transition with original members and no sharp or extensive
projections.
(e) Electrolytic
action. Protect dissimilar metals from electrolytic action when they are
joined.
(f) Welding. All welding
must be according to the "Code for Welding in Building Construction"
(AWSD1.0-1966).
(g) Protection from
deterioration. Paint or treat metal ladders and attachments to resist corrosion
and rusting when necessary. Ladders with individual metal rungs imbedded in
concrete, that serve as access to pits and to other areas under floors, must
have rungs with a minimum diameter of 1 inch or paint or treatment to resist
corrosion and rusting.
(4) Clearance. [Figure not included. See ED.
NOTE.]
(a) Climbing side. On fixed ladders,
the perpendicular distance from the centerline of the rungs to the nearest
permanent object on the climbing side of the ladder must be 36 inches for a
pitch of 76°, and 30 inches for a pitch of 90° (fig. 3), with minimum
clearances for intermediate pitches varying between these two limits in
proportion to the slope, except as in (4)(c) and (e) below.
(b) Ladders without cages or wells. There
must be a clear width of at least 15 inches each way from the centerline of the
ladder in the climbing space, except when cages or wells are
necessary.
(c) Ladders with cages
or baskets. Subparagraphs (4)(a) and (b) above do not cover ladders with a cage
or basket. They must conform to (5)(a)(E). Subparagraph (4)(a) above does not
cover fixed ladders in smooth-walled wells. They must conform to
(5)(a)(F).
(d) Clearance in back of
ladder. The distance from the centerline of rungs, cleats, or steps to the
nearest permanent object in back of the ladder must be not less than 7 inches,
except that when there are unavoidable obstructions, there must be minimum
clearances shown in Figure 4. [Figure not included. See ED. NOTE.]
(e) Clearance in back of grab bar. The
distance from the centerline of the grab bar to the nearest permanent object in
back of the grab bars must be not less than 4 inches. Grab bars must not
protrude on the climbing side beyond the rungs of the ladder that they
serve.
(f) Step-across distance.
The step-across distance from the nearest edge of the ladder to the nearest
edge of equipment or structure must be not more than 12 inches, or less than
2-1/2 inches (fig. 5). [Figure not included. See ED. NOTE.]
(g) Hatch cover. Counterweighted hatch covers
must open a minimum of 60° from the horizontal. The distance from the
centerline of rungs or cleats to the edge of the hatch opening on the climbing
side must be not less than 24 inches for offset wells or 30 inches for straight
wells. There must be no protruding potential hazards within 24 inches of the
centerline of rungs or cleats; any such hazards within 30 inches of the
centerline of the rungs or cleats must have deflector plates at an angle of
60° from the horizontal as shown in figure 6. The relationship of a fixed
ladder to an acceptable counterweighted hatch cover is shown in figure 7.
[Figures not included. See ED. NOTE.]
(5) Special requirements.
(a) Cages, Wells and Ladder Climbing Safety
systems.
(A) Cages, wells or laddders climbing
safety systems must be on all ladders (except chimneys) where the length of
climb is more than 24 feet but not more than 50 feet or the top of the ladder
is more than 24 feet above the ground or nearest lower landing surface.
NOTE: Design secifications for cages and wells are in Figures 8, 9 and 10.
(B) Ladders
with a length of climb more than 50 feet (except chimneys) must have a cage,
well or climbing safety system and must meet one of the following two
requirements:
(i) When using a cage or well
the ladder must be in sections, horizonitally offset, with real platforms at
least every 50 feet.
(ii) When
using a climbing safety system the ladder must have rest platforms at least
every 150 feet. [Figure not included. See ED. NOTE.]
(C) Cages must extend at least 42 inches
above the top of the landing, unless there is other acceptable protection.
(D) Cages must extend down the
ladder to a point not less than 7 feet nor more than 8 feet above the base of
the ladder. The bottom must flare not less than 4 inches or a portion of the
cage opposite ladder must extend to the base.
(E) Cages must not extend less than 27 nor
more than 28 inches from the center line of the rungs of the ladder. Cages must
not be less than 27 inches in width. The inside must be clear of projections.
Vertical bars must be at a maximum spacing of 40 degrees around the
circumference of the cage; this will give a maximum spacing of approximately
9-1/2 inches, center to center.
(F)
Ladder wells must have a clear width of at least 15 inches measured each way
from the center line of the ladder. Smooth-walled wells must be a minimum of 27
inches from the center line of rungs to the well wall on the climbing side of
the ladder. Where other obstructions on the climbing side of the ladder exist,
there must be a minimum of 30 inches from the centerline of the rungs. [Figures
not included. See ED. NOTE.]
(b) Landing platforms.
(A) Where a person has to step a distance
more than 12 inches from the center line of the rung of a ladder to the nearest
edge of a structure or equipment, there must be a landing platform. The minimum
step-across distance is 2-1/2 inches.
(B) All landings must have standard railings
and toeboards, that give safe access to the ladder. Platforms must be not less
than 24 inches wide and 30 inches long.
(C) One rung of any section of ladder must be
at the level of the landing laterally served by the ladder. Where access to the
landing is through the ladder, the rung spacing from the landing platform to
the first rung below the landing must be the same as on the ladder.
(c) Ladder extensions. The side
rails of through or side step ladder extensions must extend 3-1/2 feet above
parapets and landings. For through ladder extensions, omit the rungs from the
extension. There must be not less than 18 nor more than 24 inches clearance
between rails. For side step or offset fixed ladder sections, at landings, the
side rails and rungs must extend to the next regular rung beyond or above the
3-1/2 foot minimum (fig.11). [Figure not included. See ED. NOTE.]
(d) Grab bars. Space grab bars by a
continuation of the rung spacing when they are horizontal. Vertical grab bars
must have the same spacing as the ladder side rails. Grab bar diameters must be
the equivalent of the round rung diameters.
(6) Pitch.
(a) Preferred pitch. The preferred pitch of
fixed ladders is between 75° and 90° with the horizontal (fig. 12).
[Figure not included. See ED. NOTE.]
(b) Substandard pitch. Fixed ladders are
substandard if they are between 60° and 75° with the horizontal.
Substandard fixed ladders are allowed only where necessary to meet conditions
of installation.
(c) Scope of
coverage in this section. This section covers only fixed ladders between
60° and 90° with the horizontal.
(d) Pitch more than 90°. No ladder may be
more than 90° with the horizontal.
(7) Maintenance. All ladders must be in safe
condition. Inspect ladders at intervals determined by use and
exposure.
Notes
The figures referenced in this rule are not printed in the OAR Compilation. Copies are available from the agency.
Stat. Auth.: ORS 654.025(2) & ORS 656.726(3)
Stats. Implemented: ORS 654.001 - ORS 654.295
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.