Or. Admin. Code § 603-029-0710 - Chemical; Carbon Dioxide
The slaughtering of sheep, calves and swine with the use of carbon dioxide gas and the handling in connection therewith, in compliance with the provisions contained in this rule, are hereby designated and approved as humane methods of slaughtering and handling of such animals.
(1) Administration of gas, required effect;
handling.
(a) The carbon dioxide gas shall be
administered in a chamber in accordance with this rule so as to produce
surgical anesthesia in the animals before they are shackled, hoisted, thrown,
cast, or cut. The animals shall be exposed to the carbon dioxide gas in a way
that will accomplish the anesthesia quickly and calmly, with a minimum of
excitement and discomfort to the animals. In swine, carbon dioxide may be
administered to induce death in the animals before they are shackled, hoisted,
thrown, cast, or cut.
(b) The
driving or conveying of the animals to the carbon dioxide chamber shall be done
with a minimum of excitement and discomfort to the animals. Delivery of calm
animals to the anesthesia chamber is essential since the induction, or early
phase, of anesthesia is less violent with docile animals. Among other things
this requires that, in driving animals to the anesthesia chamber, electrical
equipment be used as little as possible and with the lowest effective
voltage.
(c) On emerging from the
carbon dioxide tunnel, the animals shall be in a state of surgical anesthesia
and shall remain in this condition throughout shackling, sticking, and
bleeding, except for swine in which death has been induced by the
administration of carbon dioxide. Asphyxia or death from any cause shall not be
produced in animals before bleeding, except for swine in which death has been
induced by the administration of carbon dioxide.
(2) Facilities and procedures.
(a) General requirements for gas chambers and
auxiliary equipment; operator.
(A) The carbon
dioxide gas shall be administered in a tunnel which is designed to permit the
effective exposure of the animal. Two types of tunnels, based on the same
principle, are in common use for carbon dioxide anesthesia. They are the "U"
type tunnel and the "Straight Line" type tunnel, and are based on the principle
that carbon dioxide gas has a higher specific gravity than air. The tunnels are
open at both ends for entry and exit of animals and have a depressed central
section. Anesthetizing, or, in the case of swine, death-inducing, carbon
dioxide concentrations are maintained in the central sections of the tunnels.
Effective anaesthetization is produced in these central sections. Animals are
driven from holding pens through pathways constructed of large-diameter pipe or
smooth metal and onto continuous conveyor devices that move the animals through
the tunnels. The animals are either compartmentalized on the conveyors by
mechanical impellers synchronized with the conveyor or they are otherwise
prevented from crowding. While impellers are used to compartmentalize the
animals, mechanically or manually operated gates are used to move the animals
onto the conveyors. Surgically anaesthetized animals, or killed swine, are
moved out of the tunnels by the same continuous conveyors that moved them into
and through the carbon dioxide gas.
(B) Flow of animals into and through the
carbon dioxide chamber is dependent on one operator. The operation or stoppage
of the conveyor is entirely dependent upon this operator. It is necessary that
the operator be skilled, attentive, and aware of the operator's responsibility.
Overdosages and death of animals can be brought about by carelessness of this
individual.
(b) Special
requirements for gas chamber and auxiliary equipment. The ability of
anesthetizing equipment to perform with maximum efficiency is dependent on its
proper design and efficient mechanical operation. Pathways, compartments, gas
chambers, and all other equipment used must be designed to accommodate properly
the species of animals being anesthetized. They shall be free from
pain-producing restraining devices. Injury of animals must be prevented by the
elimination of sharp projections or exposed wheels or gears. There shall be no
unnecessary holes, spaces or openings where feet or legs of animals may be
injured. Impellers or other devices designed to mechanically move or drive
animals or otherwise keep them in motion or compartmentalized shall be
constructed of flexible or well-padded rigid material. Power activated gates
designed for constant flow of animals to anesthetizing equipment shall be so
fabricated that they will not cause injury. All equipment involved in
anesthetizing animals shall be maintained in good repair.
(c) Gas. Maintenance of a uniform carbon
dioxide concentration and distribution in the anesthesia chamber is a vital
aspect of producing surgical anesthesia. This may be assured by reasonably
accurate instruments which sample and analyze carbon dioxide gas concentration
within the chamber throughout anesthetizing operations. Gas concentration shall
be maintained uniform so that the degree of anesthesia in exposed animals will
be constant. Carbon dioxide gas supplied to anesthesia chambers may be from
controlled reduction of solid carbon dioxide or from a controlled liquid
source. In either case the carbon dioxide shall be supplied at a rate
sufficient to anesthetize adequately and uniformly the number of animals
passing through the chamber. Sampling of gas for analysis shall be made from a
representative place or places within the chamber and on a continuing basis.
Gas concentrations and exposure time shall be graphically recorded throughout
each day's operation. Neither carbon dioxide nor atmospheric air used in the
anesthesia chambers shall contain noxious or irritating gases. Each day before
equipment is used for anesthetizing animals, proper care shall be taken to mix
adequately the gas and air within the chamber. All gas producing and control
equipment shall be maintained in good repair and all indicators, instruments,
and measuring devices must be available for inspection by Program inspectors
during anesthetizing operations and at other times. An exhaust system must be
provided so that, in case of equipment failure, non-uniform carbon dioxide
concentrations in the gas tunnel or contamination of the ambient air of the
establishment will be prevented.
Notes
Statutory/Other Authority: ORS 603.085, ORS 619.042 & ORS 619.046
Statutes/Other Implemented: ORS 619.042, ORS 603.059 & ORS 603.065
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.