25 Pa. Code § 78a.73 - General provision for well construction and operation
(a) The operator shall construct and operate
the well in accordance with this chapter and ensure that the integrity of the
well is maintained and health, safety, environment and property are
protected.
(b) The operator shall
prevent gas, oil, brine, completion and servicing fluids, and any other fluids
or materials from below the casing seat from entering fresh groundwater, and
shall otherwise prevent pollution or diminution of fresh groundwater.
(c) The operators of active, inactive,
abandoned, and plugged and abandoned wells identified as part of an area of
review survey conducted under §
78a.52a (relating to area of
review) that likely penetrate within 1,500 feet measured vertically from the
stimulation perforations, if known, shall be notified. Notice shall be provided
at least 30 days prior to the start of drilling the well or at the time the
permit application is submitted to the Department if the start of drilling is
planned less than 30 days from the date of permit issuance. Orphan wells,
abandoned wells, and plugged and abandoned wells identified as part of an area
of review survey conducted under §
78a.52a that either penetrate
within 1,500 feet measured vertically from the stimulation perforations or have
an unknown true vertical depth shall be visually monitored during stimulation
activities. The operator shall immediately notify the Department of any change
to a well being monitored, of any treatment pressure or volume changes
indicative of abnormal fracture propagation at the well being stimulated or if
otherwise made aware of a confirmed well communication incident associated with
their stimulation activities. Notice shall be provided to the Department
electronically through the Department's web site. In an event such as this, the
operator shall cease stimulating the well that is the subject of the area of
review survey and take action to prevent pollution of waters of the
Commonwealth or discharges to the surface. The operator may not resume
stimulation of the well that is the subject of the area of review survey
without Department approval.
(d) An
operator that alters an orphan well, or an abandoned well or plugged and
abandoned well by hydraulic fracturing shall plug the altered well in
accordance with this chapter, or the operator may adopt the altered well and
place it into production.
(e) After
a well has been completed, recompleted, reconditioned or altered the operator
shall prevent surface shut-in pressure and surface producing back pressure
inside the surface casing or coal protective casing from exceeding the
following pressure: 80% multiplied by 0.433 psi per foot multiplied by the
casing length (in feet) of the applicable casing.
(f) After a well has been completed,
recompleted, reconditioned or altered, if the surface shut-in pressure or
surface producing back pressure exceeds the pressure as calculated in
subsection (e), the operator shall take action to prevent the migration of gas
and other fluids from lower formations into fresh groundwater. To meet this
standard the operator may cement or install on a packer sufficient intermediate
or production casing or take other actions approved by the Department. This
section does not apply during testing for mechanical integrity in accordance
with State or Federal requirements.
(g) Excess gas encountered during drilling,
completion or stimulation shall be flared, captured or diverted away from the
drilling rig in a manner that does not create a hazard to the public health or
safety.
(h) The well must be
equipped with a check valve to prevent backflow from the pipelines into the
well.
Notes
This section cited in 25 Pa. Code § 78a.52a (relating to area of review); 25 Pa. Code § 78a.83 (relating to surface and coal protective casing and cementing procedures); 25 Pa. Code § 78a.83b (relating to casing and cementing-lost circulation); and 25 Pa. Code § 78a.88 (relating to mechanical integrity of operating wells).