34 Pa. Code § 47.234 - Metal railings other than pipe
(a)
Angle. Metal railings other than pipe shall be of a section
at least equal in strength to that of 1 1/2 by 1 1/2 by 3/16 inch angles.
Reference should be made to Plate 2 of the Appendix.
(b)
Midrails. The middle
railings shall be of a section at least equal in strength to the minimum
requirement for top railings.
(c)
Posts. The posts or uprights shall be of a section at least
equal in strength to the minimum requirements for railings. Posts which are an
integral part of the under or over structure are acceptable if they meet the
spacing requirements of §
47.232 (relating to construction)
and strength requirements of §
47.233 (relating to pipe
railings).