Utah Admin. Code R307-353-8 - Add-On Controls Systems Operations
(1) If an add-on control system is used, the
owner or operator shall install and maintain in accordance with the
manufacturer recommendations and maintain 90% or greater capture and control
efficiency. The overall capture and control efficiency shall be determined
using EPA approved methods, as follows.
(a)
The capture efficiency of a VOC emission control system's VOC collection device
shall be determined according to EPA's "Guidelines for Determining Capture
Efficiency," January 9, 1995 and 40 CFR Part 51, Appendix M, Methods 204-204F,
as applicable.
(b) The control
efficiency of a VOC emission control system's VOC control device shall be
determined using test methods in Appendices A-1, A-6, and A-7 to 40 CFR Part
60, for measuring flow rates, total gaseous organic concentrations, or
emissions of exempt compounds, as applicable.
(c) An alternative test method may be
substituted for the preceding test methods after review and approval by the EPA
Administrator.