Utah Admin. Code R307-504-4 - Tank Truck Loading Requirements

(1) Tanker trucks used for intermediate hydrocarbon liquid or produced water shall be loaded using bottom filling or a submerged fill pipe.
(2) VOC emissions during truck loading operations shall be controlled at all times using a vapor capture line. The vapor capture line shall be connected from the tanker truck to a control device or process, resulting in a minimum 95 percent VOC destruction efficiency.
(a) Well sites in operation on January 1, 2018 shall comply with R307-504-4(2) no later than July 1, 2019.

Notes

Utah Admin. Code R307-504-4
Adopted by Utah State Bulletin Number 2014-21, effective 10/7/2014 Amended by Utah State Bulletin Number 2018-7, effective 3/5/2018

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.