Utah Admin. Code R315-261-1032 - Air Emission Standards for Process Vents - Process Vents
(a) The remanufacturer or other person that
stores or treats hazardous secondary materials in hazardous secondary material
management units with process vents associated with distillation,
fractionation, thin-film evaporation, solvent extraction, or air or steam
stripping operations managing hazardous secondary material with organic
concentrations of at least 10 ppmw shall either:
(1) Reduce total organic emissions from all
affected process vents at the facility below 1.4 kg/h (3 lb/h) and 2.8 Mg/yr
(3.1 tons/yr), or
(2) Reduce, by
use of a control device, total organic emissions from all affected process
vents at the facility by 95 weight percent.
(b) If the remanufacturer or other person
that stores or treats the hazardous secondary material installs a closed-vent
system and control device to comply with the provisions of Subsection
R315-261-1032(a) the closed-vent system and control device shall meet the
requirements of Section
R315-261-1033.
(c) Determinations of vent emissions and
emission reductions or total organic compound concentrations achieved by add-on
control devices may be based on engineering calculations or performance tests.
If performance tests are used to determine vent emissions, emission reductions,
or total organic compound concentrations achieved by add-on control devices,
the performance tests shall conform with the requirements of Subsection
R315-261-1034(c).
(d) When a remanufacturer or other person
that stores or treats the hazardous secondary material and the Director do not
agree on determinations of vent emissions and/or emission reductions or total
organic compound concentrations achieved by add-on control devices based on
engineering calculations, the procedures in Subsection
R315-261-1034(c)
shall be used to resolve the disagreement.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.