Utah Admin. Code R315-264-1055 - Standards: Sampling Connection Systems
(a) Each sampling connection system shall be
equipped with a closed-purge, closed-loop, or closed-vent system. This system
shall collect the sample purge for return to the process or for routing to the
appropriate treatment system. Gases displaced during filling of the sample
container are not required to be collected or captured.
(b) Each closed-purge, closed-loop, or
closed-vent system as required in Subsection R315-264-1055(a) shall meet one of
the following requirements:
(1) Return the
purged process fluid directly to the process line;
(2) Collect and recycle the purged process
fluid; or
(3) Be designed and
operated to capture and transport all the purged process fluid to a waste
management unit that complies with the applicable requirements of Sections
R315-264-1084
through 1086 or a control device that complies with the requirements of Section
R315-264-1060.
(c) In-situ sampling
systems and sampling systems without purges are exempt from the requirements of
Subsections R315-264-1055(a) and (b).