Utah Admin. Code R315-264-1065 - Reporting Requirements
(a) A semiannual
report shall be submitted by owners and operators subject to the requirements
of Sections
R315-264-1050
through 1065 to the Director by dates specified by the Director. The report
shall include the following information:
(1)
The Environmental Protection Agency identification number, name, and address of
the facility.
(2) For each month
during the semiannual reporting period:
(i)
The equipment identification number of each valve for which a leak was not
repaired as required in Subsection
R315-264-1057(d).
(ii) The equipment identification
number of each pump for which a leak was not repaired as required in
Subsections
R315-264-1052(c)
and (d)(6).
(iii) The equipment identification number of
each compressor for which a leak was not repaired as required in Subsection
R315-264-1053(g).
(3) Dates of hazardous
waste management unit shutdowns that occurred within the semiannual reporting
period.
(4) For each month during
the semiannual reporting period, dates when the control device installed as
required by Sections
R315-264-1052,
1053, 1054, or 1055 exceeded or operated outside of the design specifications
as defined in Subsection
R315-264-1064(e)
and as indicated by the control device monitoring required by Section
R315-264-1060
and was not corrected within 24 hours, the duration and cause of each
exceedance, and any corrective measures taken.
(b) If, during the semiannual reporting
period, leaks from valves, pumps, and compressors are repaired as required in
Subsections
R315-264-1057(d),
1052(c) and (d)(6), and 1053(g), respectively, and the control device does not
exceed or operate outside of the design specifications as defined in Subsection
R315-264-1064(e)
for more than 24 hours, a report to the Director is not required.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.