Utah Admin. Code R432-5-12 - Details and Finishes
(1) Grab bars shall
be installed in each toilet room in accordance with the Americans with
Disabilities Act and Architectural Barriers Act Accessibility
Guidelines.
(2) Corridor and
hallway handrails shall comply with the Americans with Disabilities Act and
Architectural Barriers Act Accessibility Guidelines. The top of the rail shall
be 34 inches above the floor, except for areas serving children and other
special care areas. Corridor handrails shall have a graspable profile with
finger wrap recesses not less than 5/8 inches deep. Handrails shall have color
that contrasts to the wall.
(3)
Cubicle curtains and draperies shall be affixed to permanently mounted tracks
or rods. Portable curtains or visual barriers are not permitted.
(4) Signs shall be provided as follows:
(a) general and circulation direction signs
in corridors;
(b) identification at
each door;
(c) emergency
directional signs; and
(d) any
signs in corridors shall comply with the Americans with Disabilities Act and
Architectural Barriers Act Accessibility Guidelines.
Notes