Utah Admin. Code R70-101-8 - Sterilization Requirements for New Fill Material

(1) A sterilizer shall clean and sterilize any wool, feathers, down, shoddy, and hair before using it as a new filling material.
(2) The department allows the following methods for sterilization.
(a)
(i) Pressure Steam.
(ii) Expose the material to treatment by steam at 15 PSI (.104 mPA) for 30 minutes or 20 PSI (.0138 mPA) for 20 minutes.
(iii) The gauge for registering steam pressure shall be visible from the outside of the room or chamber.
(b)
(i) Streaming Steam.
(ii) Two applications of streaming steam maintained for one hour each, applied at intervals using not less than six nor more than 24 hours.
(iii) When streaming steam is employed, the valved outlets shall be provided near the bottom and the top of the room or chamber.
(c)
(i) Heat.
(ii) A temperature of 235 degrees F held for two hours within a closed container.
(3) Upon request, the department may approve other methods of sterilization.

Notes

Utah Admin. Code R70-101-8
Amended by Utah State Bulletin Number 2015-16, effective 7/22/2015 Amended by Utah State Bulletin Number 2017-4, effective 1/26/2017 Amended by Utah State Bulletin Number 2020-12, effective 6/8/2020 Amended by Utah State Bulletin Number 2022-08, effective 4/5/2022 Amended by Utah State Bulletin Number 2023-08, effective 4/4/2023 Amended by Utah State Bulletin Number 2024-05, effective 2/2/2024, exp. 6/1/2024 (Emergency) Amended by Utah State Bulletin Number 2024-12, effective 6/1/2024, exp. 9/29/2024 (Emergency) Amended by Utah State Bulletin Number 2024-20, effective 9/30/2024, exp. 1/28/2025 (Emergency) Adopted by Utah State Bulletin Number 2024-21, effective 10/23/2024

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.