Utah Admin. Code R70-101-8 - Sterilization Requirements for New Fill Material
(1) A sterilizer
shall clean and sterilize any wool, feathers, down, shoddy, and hair before
using it as a new filling material.
(2) The department allows the following
methods for sterilization.
(a)
(i) Pressure Steam.
(ii) Expose the material to treatment by
steam at 15 PSI (.104 mPA) for 30 minutes or 20 PSI (.0138 mPA) for 20
minutes.
(iii) The gauge for
registering steam pressure shall be visible from the outside of the room or
chamber.
(b)
(i) Streaming Steam.
(ii) Two applications of streaming steam
maintained for one hour each, applied at intervals using not less than six nor
more than 24 hours.
(iii) When
streaming steam is employed, the valved outlets shall be provided near the
bottom and the top of the room or chamber.
(c)
(i)
Heat.
(ii) A temperature of 235
degrees F held for two hours within a closed container.
(3) Upon request, the department
may approve other methods of sterilization.