Wash. Admin. Code § 204-21-190 - School bus warning lamps
(1) If
the bus is a privately owned school bus or private carrier bus, then it must
not use the eight lamp warning system unless such use is in conformance with
the rules and regulations set forth by the superintendent of public instruction
in chapters 392-143 and 392-145 WAC. The requirements for private carrier buses
may be found under chapter 204-32 WAC.
(2) If the bus is a school bus owned and
operated by any public school district and all privately owned school buses
operated under contract with a school district in the state and used for the
transportation of public school children, then the warning lamp system must:
(a) Be operated in accordance with the
regulations set forth in chapter 392-145 WAC.
(b) Consist of a total of eight lamps
conforming to SAE Standard J887 or the standard in effect for such lamp at the
time it was manufactured. Two amber and two red on both the front and rear of
the bus. The amber lamps must be mounted inboard of the red lamps.
(c) Be mounted as high as practicable on the
bus body and as near the outside edges of the body as curvature
permits.
(d) Have shielding to
protect the lamps from the elements and/or be mounted flush with the body
surface.
(e) Be mounted on a
background that is painted black and extends a minimum of three inches outward
from the lamps.
(f) Be mounted and
aimed as specified in 49 C.F.R. Part 571.108 (FMVSS 108) and SAE Standard
J887a.
(g) Be clearly visible from
a distance of at least five hundred feet in normal sunlight.
(h) Be activated only by means of a manually
operated switch. Such activation will cause the right and left amber lamps to
flash alternately until the stop signal arm is extended, or the bus entrance
door is opened, at which time the amber lamps must be automatically deactivated
and the right and left red lamps must be automatically activated. Whenever the
warning lamp system has been activated, opening of the entrance door must
automatically deactivate the amber lamps, cause the stop signal arm to extend,
and activate the red lamps. Automatic extension of the stop signal arm does not
apply to systems equipped with a manually operated stop signal arm.
(i) Have all lamps flashing at a rate from
sixty to one hundred twenty times per minute and must reach full brilliance
during each cycle.
(j) Have lamp
controls which must consist of:
(i) The master
or sequencing switch which must be in plain view and mounted within easy reach
of the driver, and which must activate the system sequencing and deactivate the
system at any time during the sequence.
(ii) An override switch which must
automatically activate the red lamps whenever the stop signal arm is extended
even though the master control switch is turned off, and which must
automatically deactivate the amber lamps if previously activated regardless of
the then present normal state of sequencing or entrance door position. Such
override switch must be designed and installed so as to function with air,
vacuum, electric, or manually operated stop signal arms. The stop signal arm
must be capable of being extended at any time, regardless of the position of
the entrance door. The opening of the entrance door must not cause extension of
the stop signal arm, or the activation of the red lamps unless the master
switch has been activated.
(iii) A
minimum of two pilot lamps, one amber and one red, each of which must flash
when the like colored warning lamps are in operation. Pilot lamps which show
the operation of each individual lamp are permissible. All pilot indicators
must be located so as to be clearly visible to the driver.
Notes
Statutory Authority: RCW 46.37.005 and 46.37.320. 12-03-084, § 204-21-190, filed 1/13/12, effective 2/13/12; 08-19-104, § 204-21-190, filed 9/17/08, effective 10/18/08.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.