Wash. Admin. Code § 296-809-60002 - Make sure the following conditions are met if using alternative methods
(1) You may enter
permit-required confined spaces without a permit using alternative methods when
you have monitoring and inspection data that supports the following:
(a) You have eliminated all the
hazards1; or
(b) You have eliminated all of the physical
hazards1,2, and continuous forced air ventilation
controls the actual or potential hazardous atmosphere. You must also have
monitoring data that demonstrates the use of continuous forced air ventilation
will maintain the permit-required confined space for safe entry. In the event
the ventilation system stops working, entrants can exit the space
safely.
(2) You must
have written documentation for the entrants before each entry that includes the
following information:
(a) The location of
the space;
(b) Date of the
entry;
(c) Duration of the
entry;
(d) The hazards of the space
and the work;
(e) The specific
measures used to eliminate the hazards1;
(f) The ventilation system used to control
atmospheric hazards, when applicable, direct reading instruments used to test
the atmosphere, and results of the atmospheric testing that demonstrate the
absence of a hazardous atmosphere;1,2
(g) All conditions that required evacuation
of the space3; and
(h) The name, title, and signature of the
entry supervisor ensuring safe entry procedures.
(3) You must make sure all documentation
produced is available to each affected employee and their authorized
representative.
(4) You must make
sure all monitoring and inspection data is documented and available to each
affected employee and their authorized representative.
(5) If you must enter prior to the completion
of the hazard elimination, you must perform the entry according to WAC
296-809-500 Permit entry
procedures. For example -To collect monitoring inspection data or to apply
hazard elimination measures.
| Notes: | 1 For the purposes of this section, energy control procedures must isolate the space and result in the elimination of the hazards including applicable stored energy. Evaluate your energy control procedures (lockout) to ensure they fully eliminate the hazards when used. See chapter 296-803 WAC, Lockout/tagout (control of hazardous energy). Tagout is an example of a method not considered to eliminate hazards. |
| 2 Controlling atmospheric hazards through forced air ventilation does not eliminate the hazards. | |
| 3 Do not use alternative methods to enter a continuous system unless you can do the following: | |
| * Completely isolate the area entered from the rest of the space; | |
| * Demonstrate that the conditions that caused the hazard or potential hazard no longer exist within the system for the duration of the entry including engulfment; and | |
| * You have sufficient quantities of continuous ventilation to control the atmospheric hazard. | |
| See Appendix J for Alternative Methods Documentation by visiting the labor and industries web site at http://www.lni.wa.gov/safety/rules/chapter/809/ . |
Notes
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 04-03-081, § 296-809-60002, filed 1/20/04, effective 5/1/04.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.