010-12 Wyo. Code R. §§ 12-4 - Vehicle and Equipment Standards
(a) All containers,
tanks, hoses, fittings, caps and other equipment used to haul, store or
transfer bulk water shall:
(b)
All pumps must be constructed of food grade, corrosion resistant materials, and
have permanently sealed, self-lubricating bearings.
(c) All parts of the tank, filling system,
delivery system and associated pumps and hoses must be readily accessible for
cleaning and inspection.
(d) All
hoses and tubing shall:
(i) Be provided with
threaded or clamped caps; and
(ii)
The caps shall be in place at all times the fitting or hose is not in use.
(A) All caps shall be appropriately tethered
to equipment to prevent loss and misuse.
(e) When hose bibs are available for filling
canteens or portable water containers, a vacuum breaker shall be used to
prevent backflow contamination.
(i) All hose
bibs shall be provided with caps and shall be kept capped except when in
use.
(f) All bulk tank
openings and valves shall be kept closed and completely sealed at all times to
prevent contamination from entering the tank.
(g) A manhole shall be provided for routine
maintenance, cleaning and sanitizing.
(i) The
manhole shall be large enough to enter for inspection.
(h) A drain at the lowest point in the tank
shall be provided to allow for complete drainage.
(i) All reducers, adapters, pipe fittings and
any other water-handling equipment carried on board must be stored protected in
dust-proof containers.
(j) All tank
valves and other openings shall be kept closed, latched, and sealed when not in
use.