010-3 Wyo. Code R. §§ 3-21 - Heaters and Boilers, Installation and Testing
(a) All
heating equipment using either fossil fuels such as natural gas, liquid
petroleum gas, No. 2 fuel oil, or electric heating equipment for heating pool
water for pools and spas shall:
(i) Comply
with ANSI Z21.56, Standards for Gas-Fired Heaters; or
(ii) Comply with UL 1261, Standard for
Electric Heaters or UL 559, Standards for Heat Pumps.
(iii) Be installed on a surface with
sufficient structural strength to support the heater when it is full of water
and operating;
(iv) Be level and
stationary after plumbing, gas and/or electrical connections are completed.
(A) Heaters requiring a non-combustible
surface per the manufacturer shall be placed on a concrete or other acceptable
surface in accordance with ANSI Z21.56, Standards for Gas-Fired
Heaters.
(v) Be
installed and maintained with at least the minimum clearances to combustibles
for which the heater has been tested as specified by the
manufacturer;
(vi) Have adequate
ventilation in order to ensure proper operation; and (vii) Be grounded and
bonded to reduce electrical shock hazard.
(b) Heaters with electronic ignition shall be
wired in series with the circulation pump to ensure they will not turn on when
the pump is off.
(c) Water flow
through the heater, bypass plumbing, cross-connection protection, and heat
sinks shall be in accordance with the manufacturer's specifications and with
the requirements of state and/or local regulatory authorities.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.