Number of poles |
Nominal Full-Load Efficiency |
|||||
---|---|---|---|---|---|---|
Open Motors |
Closed Motors |
|||||
6 |
4 |
2 |
6 |
4 |
2 |
|
Motor Horsepower |
||||||
1 |
80.0 |
82.5 |
....... |
80.0 |
82.5 |
75.5 |
1.5 |
84.0 |
84.0 |
82.5 |
85.5 |
84.0 |
82.5 |
2 |
85.5 |
84.0 |
84.0 |
86.5 |
84.0 |
84.0 |
3 |
86.5 |
86.5 |
84.0 |
87.5 |
87.5 |
85.5 |
5 |
87.5 |
87.5 |
85.5 |
87.5 |
87.5 |
87.5 |
7.5 |
88.5 |
88.5 |
87.5 |
89.5 |
89.5 |
88.5 |
10 |
90.2 |
89.5 |
88.5 |
89.5 |
89.5 |
89.5 |
15 |
90.2 |
91.0 |
89.5 |
90.2 |
91.0 |
90.2 |
20 |
91.0 |
91.0 |
90.2 |
90.2 |
91.0 |
90.2 |
25 |
91.7 |
91.7 |
91.0 |
91.7 |
92.4 |
91.0 |
30 |
92.4 |
92.4 |
91.0 |
91.7 |
92.4 |
91.0 |
40 |
93.0 |
93.0 |
91.7 |
93.0 |
93.0 |
91.7 |
50 |
93.0 |
93.0 |
92.4 |
93.0 |
93.0 |
92.4 |
60 |
93.6 |
93.6 |
93.0 |
93.6 |
93.6 |
93.0 |
75 |
93.6 |
94.1 |
93.0 |
93.6 |
94.1 |
93.0 |
100 |
94.1 |
94.1 |
93.0 |
94.1 |
94.5 |
93.6 |
125 |
94.1 |
94.5 |
93.6 |
94.1 |
94.5 |
94.5 |
150 |
94.5 |
95.0 |
93.6 |
95.0 |
95.0 |
94.5 |
200 |
94.5 |
95.0 |
94.5 |
95.0 |
95.0 |
95.0 |
|
|
Refrigerators with solid doors |
0.10 |
Refrigerators with transparent doors |
0.12 |
Freezers with solid doors |
0.40 |
Freezers with transparent doors |
0.75 |
Refrigerators/freezers with solid doors the greater of |
0.27 |
Equipment Type |
Type of Cooling |
Harvest Rate (lbs ice/24 hours) |
Maximum Energy Use (kWh/100 lbs Ice) |
Maximum Condenser Water Use (gal/100 lbs Ice) |
---|---|---|---|---|
Water use is for the condenser only and does not include potable water used to make ice. |
||||
Ice Making Head |
Water |
<500 |
7.80–0.0055H |
200–0.022H |
|
|
ª500 and <1436 |
5.58–0.0011H |
200–0.022H |
|
|
ª1436 |
4.0 |
200–0.022H |
Ice Making Head |
Air |
<450 |
10.26–0.0086H |
Not Applicable |
|
|
ª450 |
6.89–0.0011H |
Not Applicable |
Remote Condensing (but not remote compressor) |
Air |
<1000 |
8.85–0.0038H |
Not Applicable |
|
|
ª1000 |
5.10 |
Not Applicable |
Remote Condensing and Remote Compressor |
Air |
<934 |
8.85–0.0038H |
Not Applicable |
|
|
ª934 |
5.3 |
Not Applicable |
Self Contained |
Water |
<200 |
11.40–0.019H |
191–0.0315H |
|
|
ª200 |
7.60 |
191–0.0315H |
Self Contained |
Air |
<175 |
18.0–0.0469H |
Not Applicable |
|
|
ª175 |
9.80 |
Not Applicable |
The requirements of paragraph (1)(E)(i) for electronically commutated motors shall take effect January 1, 2009, unless, prior to that date, the Secretary determines that such motors are only available from 1 manufacturer.
Not later than January 1, 2012, the Secretary shall publish performance-based standards for walk-in coolers and walk-in freezers that achieve the maximum improvement in energy that the Secretary determines is technologically feasible and economically justified.
Not later than January 1, 2020, the Secretary shall publish a final rule to determine if the standards established under paragraph (4) should be amended.
Subparagraph (C) of paragraph (1) shall not apply to a walk-in cooler or walk-in freezer component if the component manufacturer has demonstrated to the satisfaction of the Secretary that the component reduces energy consumption at least as much as if such subparagraph were to apply. In support of any demonstration under this paragraph, a manufacturer shall provide to the Secretary all data and technical information necessary to fully evaluate its application.
If the Secretary, acting pursuant to section 6312(b) of this title, includes as covered equipment solid state lighting power supply circuits, drivers, or devices described in section 6291(36)(A)(ii) of this title, the Secretary may prescribe under this part, not earlier than 1 year after the date on which a test procedure has been prescribed, an energy conservation standard for such equipment.