Fla. Admin. Code Ann. R. 64E-5.106 - Units of Exposure and Dose
QUALITY FACTORS AND ABSORBED DOSE EQUIVALENCIES
Absorbed Dose Equal |
||
Quality Factor |
to a Unit Dose |
|
TYPE OF RADIATION |
(Q) |
Equivalenta |
X, gamma, or beta radiation and |
1 |
1 |
high-speed electrons |
||
Alpha particles, multiple-charged |
20 |
0.05 |
particles, fission fragments and heavy |
||
particles of unknown charge |
||
Neutrons of unknown energy |
10 |
0.1 |
High-energy protons |
10 |
0.1 |
a Absorbed dose in rad equal to 1 rem or the absorbed dose in gray equal to 1 Sv.
MEAN QUALITY FACTORS, Q, AND FLUENCE PER UNIT DOSE EQUIVALENT FOR MONOENERGETIC NEUTRONS
Fluence per Unit |
Fluence per Unit |
|||
Neutron |
Quality |
Dose Equivalentb |
Dose Equivalentb |
|
Energy |
Factora |
(neutrons |
(neutrons |
|
(MeV) |
(Q) |
cm-2 rem-1) |
cm-2 Sv-1) |
|
(thermal) |
2.5 x 10-8 |
2 |
980 x 106 |
980 x 108 |
1 x 10-7 |
2 |
980 x 106 |
980 x 108 |
|
1 x 10-6 |
2 |
810 x 106 |
810 x 108 |
|
1 x 10-5 |
2 |
810 x 106 |
810 x 108 |
|
1 x 10-4 |
2 |
840 x 106 |
840 x 108 |
|
1 x 10-3 |
2 |
980 x 106 |
980 x 108 |
|
1 x 10-2 |
2.5 |
1010 x 106 |
1010 x 108 |
|
1 x 10-1 |
7.5 |
170 x 106 |
170 x 108 |
|
5 x 10-1 |
11 |
39 x 106 |
39 x 108 |
|
1 |
11 |
27 x 106 |
27 x 108 |
|
2.5 |
9 |
29 x 106 |
29 x 108 |
|
5 |
8 |
23 x 106 |
23 x 108 |
|
7 |
7 |
24 x 106 |
24 x 108 |
|
10 |
6.5 |
24 x 106 |
24 x 108 |
|
14 |
7.5 |
17 x 106 |
17 x 108 |
|
20 |
8 |
16 x 106 |
16 x 108 |
|
40 |
7 |
14 x 106 |
14 x 108 |
|
60 |
5.5 |
16 x 106 |
16 x 108 |
|
1 x 102 |
4 |
20 x 106 |
20 x 108 |
|
2 x 102 |
3.5 |
19 x 106 |
19 x 108 |
|
3 x 102 |
3.5 |
16 x 106 |
16 x 108 |
|
4 x 102 |
3.5 |
14 x 106 |
14 x 108 |
aValue of quality factor at the point where the dose equivalent is maximum in a 30-cm diameter cylinder tissue-equivalent phantom.
bMonoenergetic neutrons incident normally on a 30-cm diameter cylinder tissue-equivalent phantom.
Notes
Rulemaking Authority 404.042, 404.051, 404.061 FS. Law Implemented 404.022(2) FS.
New 1-1-94, Formerly 10D-91.113.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
QUALITY FACTORS AND ABSORBED DOSE EQUIVALENCIES
Absorbed Dose Equal | ||
Quality Factor | to a Unit Dose | |
TYPE OF RADIATION | (Q) | Equivalenta |
X, gamma, or beta radiation and | 1 | 1 |
high-speed electrons | ||
Alpha particles, multiple-charged | 20 | 0.05 |
particles, fission fragments and heavy | ||
particles of unknown charge | ||
Neutrons of unknown energy | 10 | 0.1 |
High-energy protons | 10 | 0.1 |
a Absorbed dose in rad equal to 1 rem or the absorbed dose in gray equal to 1 Sv.
MEAN QUALITY FACTORS, Q, AND FLUENCE PER UNIT DOSE EQUIVALENT FOR MONOENERGETIC NEUTRONS
Fluence per Unit | Fluence per Unit | |||
Neutron | Quality | Dose Equivalentb | Dose Equivalentb | |
Energy | Factora | (neutrons | (neutrons | |
(MeV) | (Q) | cm-2 rem-1) | cm-2 Sv-1) | |
(thermal) | 2.5 x 10-8 | 2 | 980 x 106 | 980 x 108 |
1 x 10-7 | 2 | 980 x 106 | 980 x 108 | |
1 x 10-6 | 2 | 810 x 106 | 810 x 108 | |
1 x 10-5 | 2 | 810 x 106 | 810 x 108 | |
1 x 10-4 | 2 | 840 x 106 | 840 x 108 | |
1 x 10-3 | 2 | 980 x 106 | 980 x 108 | |
1 x 10-2 | 2.5 | 1010 x 106 | 1010 x 108 | |
1 x 10-1 | 7.5 | 170 x 106 | 170 x 108 | |
5 x 10-1 | 11 | 39 x 106 | 39 x 108 | |
1 | 11 | 27 x 106 | 27 x 108 | |
2.5 | 9 | 29 x 106 | 29 x 108 | |
5 | 8 | 23 x 106 | 23 x 108 | |
7 | 7 | 24 x 106 | 24 x 108 | |
10 | 6.5 | 24 x 106 | 24 x 108 | |
14 | 7.5 | 17 x 106 | 17 x 108 | |
20 | 8 | 16 x 106 | 16 x 108 | |
40 | 7 | 14 x 106 | 14 x 108 | |
60 | 5.5 | 16 x 106 | 16 x 108 | |
1 x 102 | 4 | 20 x 106 | 20 x 108 | |
2 x 102 | 3.5 | 19 x 106 | 19 x 108 | |
3 x 102 | 3.5 | 16 x 106 | 16 x 108 | |
4 x 102 | 3.5 | 14 x 106 | 14 x 108 |
aValue of quality factor at the point where the dose equivalent is maximum in a 30-cm diameter cylinder tissue-equivalent phantom.
bMonoenergetic neutrons incident normally on a 30-cm diameter cylinder tissue-equivalent phantom.
Notes
Rulemaking Authority 404.042, 404.051, 404.061 FS. Law Implemented 404.022(2) FS.
New 1-1-94, Formerly 10D-91.113.