Fla. Admin. Code Ann. R. 64E-5.1104 - Leak Testing of Sealed Sources
(1)
Requirements. Each licensee using sealed sources containing radioactive
material shall have the sources tested for leakage. Records of leak test
results shall be kept in units of microcuries and maintained for inspection by
the Department for 3 years after the leak test is performed or until transfer
or disposal of the sealed source.
(2) Method of testing. Tests for leakage
shall be performed only by persons specifically authorized to perform such
tests by the Department, the U.S. Nuclear Regulatory Commission, an Agreement
State, or a licensing state using a leak test kit or method approved by the
department, the U.S. Nuclear Regulatory Commission, an Agreement State, or a
Licensing State. The test sample shall be taken from the nearest accessible
point to the sealed source where contamination might accumulate. The test
sample shall be analyzed for radioactive contamination, and the analysis shall
be capable of detecting the presence of 0.005 microcurie (185 Bq) of
radioactive material on the test sample.
(3) Test frequency.
(a) Each sealed source except an energy
compensation source or ECS containing radioactive material shall be tested at
intervals not to exceed 6 months. In the absence of a certificate from a
transferor indicating that a test has been made within the 6 months before the
transfer, the sealed source shall not be used until tested. If, for any reason,
it is suspected that a sealed source may be leaking, it shall be removed from
service immediately and tested for leakage as soon as practical.
(b) Each ECS that is not exempt from testing
as specified in subsection
64E-5.1104(5),
F.A.C., below, shall be tested at intervals not to exceed 3 years. In the
absence of a certificate from a transferor that a test has been made within the
3 years before transfer, the ECS shall not be used until
tested.
(4) Removal of
Leaking or Contaminated Sources from service. If the test specified in
subsection (3), above, reveals the presence of 0.005 microcurie (185 Bq) or
more of removable radioactive material, the licensee shall remove the sealed
source from service immediately and shall cause it to be decontaminated,
repaired, or disposed of by a person licensed by the Department, the U.S.
Nuclear Regulatory Commission, an Agreement State, or a Licensing State to
perform these functions. The licensee shall check the equipment associated with
the leaking source for radioactive contamination, and if contaminated, have it
decontaminated or disposed of by a person licensed by the Department, the U.S.
Nuclear Regulatory Commission, an Agreement State or a Licensing State to
perform these functions. A report describing the equipment involved, the test
results, any contamination which resulted from the leaking source, and
corrective action taken shall be filed with the Department within 5 days of
receiving the test results.
(5)
Exemptions. The following sources are exempted from the periodic leak test
requirements of subsections
64E-5.1104(1) through
(4), F.A.C.:
(a) Hydrogen 3 sources;
(b) Sources containing radioactive material
with a half-life of 30 days or less;
(c) Sealed sources containing radioactive
material in gaseous form;
(d)
Sources of beta-emitting or gamma-emitting radioactive material with an
activity of 100 microcuries (3.7 MBq) or less; and,
(e) Sources of alpha-emitting radioactive
material with an activity of 10 microcuries (0.370 MBq) or
less.
Notes
Rulemaking Authority 404.022, 404.051(1), (4), 404.061, 404.081(1) FS. Law Implemented 404.022, 404.051(1), (5), 404.061(2), 404.081 FS.
New 4-4-89, Formerly 10D-91.12051, Amended 9-28-06.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.