Ill. Admin. Code tit. 77, § 905.100 - Aerobic Treatment Plants and NSF International/ANSI Standard 40 Wastewater Treatment Systems
a) General.
Aerobic treatment plants and NSF International/ANSI Standard 40 wastewater
treatment systems shall be tested and listed by NSF International or a
laboratory approved by ANSI and certified compliant with the International
Organization for Standardization (ISO)/International Electrotechnical
Commission (IEC) Guide 65 to determine compliance with the requirements of NSF
International/ANSI Standard 40, Residential Wastewater Treatment Systems. To
assure compliance with certification requirements and the Act and this Part,
the Department will obtain and retain from NSF International a complete list of
approved systems, approved components and approved component parts for each NSF
International/ANSI Standard 40 wastewater treatment system installed or
currently existing within the State. Until the Department receives the NSF
approval information, the system shall not be considered approved in accordance
with the Act and this Part. Standard 40 is a standard that covers an organized
and coordinated system of components that functions to treat wastewater
generated by individual residences. This Part shall allow approved aerobic
treatment plants and NSF International/ANSI Standard 40 wastewater treatment
systems to serve residential property that is occupied on a year-round or
full-time basis. Aerobic treatment plants shall not be used to serve
residential property that is used as a seasonal, weekend or part-time
residence.
b) Class II Effluent.
Aerobic treatment systems listed by NSF International or a laboratory approved
by ANSI to determine compliance with NSF International/ANSI Standard 40 for
Class II effluent shall discharge to one of the following:
1) A subsurface seepage system designed and
constructed in accordance with the requirements of Section
905.60.
2) A sand filter designed and constructed in
accordance with the requirements of Section
905.70 or
905.80.
3) A waste stabilization pond designed and
constructed in accordance with the requirements of Section
905.90.
c) Class I Effluent. NSF International/ANSI
Standard 40 wastewater treatment systems listed by NSF International or a
laboratory approved by ANSI to determine compliance with NSF International/ANSI
Standard 40 for Class I effluent shall discharge to one of the following:
1) A subsurface seepage field designed and
constructed to be at least 2/3 the size determined necessary by Section
905.60. The subsurface system
shall be installed as shallow as possible while maintaining a minimum of 6
inches of cover. There shall be at least 12 inches between the bottom of the
subsurface seepage system (soil interface) and the shallowest limiting
layer.
2) A surface discharge in
accordance with Section
905.110.
d) Sizing. Aerobic treatment plants that are
listed by NSF International or a laboratory approved by ANSI to determine
compliance with NSF International/ANSI Standard 40 as Class I and rated at 500
gallons per day will be allowed for the treatment of sewage from residential
property having up to and including 4 bedrooms. Other aerobic treatment plants
that are listed by NSF International or a laboratory approved by ANSI to
determine compliance with NSF International/ANSI Standard 40 as Class I shall
be sized as follows:
|
Minimum Rated Treatment |
|
|
Bedrooms |
Capacity-Gallons |
|
1 |
400 |
|
2 |
400 |
|
3 |
500 |
|
4 |
500 |
|
5 |
750 |
|
6 |
900 |
|
7 |
1000 |
|
8 |
1200 |
|
9 |
1350 |
|
10 |
1500 |
e)
Installation. All components of aerobic treatment plants shall be installed at
the time of the original installation. If this is not possible, a solid end cap
shall be securely placed over the end of the discharge line until the system
can be completed. This will prevent the discharge of raw sewage to the ground
surface.
f) Accessibility for
Inspection and Maintenance. The aerobic treatment plants or NSF
International/ANSI Standard 40 wastewater treatment systems shall be equipped
with one or more grade-level access manholes having a minimum inside dimension
of 18 inches that extend to 3 inches or more above the ground surface. The
manhole shall be equipped with a lid that is secured in compliance with Section
5.7.2 of NSF International/ANSI Standard 40. These manholes shall be located to
permit periodic physical inspection and maintenance of all compartments and
component parts. Component parts include submerged bearings, moving parts,
tubes, intakes, slots, filters, and other devices.
g) Service. Devices falling within the scope
of NSF International/ANSI Standard 40 require periodic maintenance to achieve
performance consistent with demonstrated capabilities. Implicit in NSF
International/ANSI Standard 40 is the recognition that assured professional
service is imperative. NSF International/ANSI Standard 40 and this Part require
a 2-year service policy to be provided as part of the initial service
agreement. (Note: The following initial service policy includes items not
included in the NSF International/ANSI Standard 40 service policy.)
1) Initial service policy. The private sewage
disposal installation contractor, through the manufacturer or the distributor
of the aerobic treatment unit, shall furnish a 2-year initial service policy to
the purchaser. This policy shall provide for:
A) Four inspection/service calls, at least
one every 6 months, that include inspection, adjustment and servicing of the
mechanical and the applicable component parts to ensure proper
function;
B) An effluent quality
inspection consisting of a visual check for color, turbidity, scum overflow,
and an examination for odors;
C)
Reporting to the owner immediately any improper operation that cannot be
corrected at the time of the inspection or service call. This shall be followed
by a written report to the owner that includes the date by which the condition
will be corrected.
2)
Continuing service policy. Each manufacturer shall make available for purchase
by the owner a continuing service policy with terms equal to the initial
service policy.
3) Standby parts.
The local distributor shall stock standby mechanical and electrical component
parts for use when the plant's mechanical or electrical components must be
removed from the site for repairs.
4) Component parts. The mechanical and
electrical component parts shall be guaranteed against any defects in materials
and workmanship as warranted.
5)
Service. Service shall be available within 2 working days following a
request.
6) Owner's manual. The
manufacturer shall provide an owner's manual with each unit. The manual shall
include the following information:
A) Model
numbers;
B) Functional description
of unit, including a statement of minimum performance requirements as
established by test;
C) Design and
flow diagrams;
D)
Warranty;
E) Replacement policy and
service policy;
F) Installation
instructions;
G) Detailed operation
and maintenance requirements (including user responsibility, parts and
service);
H) Rated service flow in
GPM (gallons per minute) or GPD (gallons per day);
I) Energy source and energy required for
proper operation of the plant; and
J) Specification of models tested under NSF
International/ANSI Standard 40.
7) Service label. A clearly visible,
permanently attached label or plate giving instructions for obtaining service
shall be placed at the audible and visual alarm.
8) Responsibility of property owner. The
property owner shall be responsible for maintaining and operating the plant in
accordance with this Part and the manufacturer's specifications.
h) Operation. Aerobic treatment
plants and NSF International/ANSI Standard 40 wastewater treatment systems
shall produce an effluent meeting the physical, chemical and biological
requirements of Section
905.110. Under normal operation
and, if an electrical or mechanical failure or other performance failure or
malfunction occurs, the design and construction of the aerobic treatment plant
or NSF International/ANSI Standard 40 wastewater treatment systems shall
prevent the discharge of wastewater from any opening that is not part of the
designed flow path of the entire treatment process and shall prevent the
discharge of wastewater that is not in compliance with Section
905.110.
i) Maintenance. If a routine service call
indicates an electrical, mechanical or performance failure or malfunction or if
routine laboratory test results indicate improper treatment, the property owner
shall immediately take action to bring the aerobic treatment plant or NSF
International/ANSI Standard 40 wastewater treatment systems into compliance
with this Part.
j) Non-residential
Use. Aerobic treatment plants and NSF International/ANSI Standard 40 wastewater
treatment systems that are listed by NSF International or a laboratory approved
by ANSI to determine compliance with NSF International/ANSI Standard 40 as
Class I will be considered for use to serve a non-residential property,
provided that all of the following are met:
1)
Total daily flows from the wastewater source into the plant are at least 75% of
the rated hydraulic capacity and do not exceed the rated hydraulic capacity of
the plant.
2) Wastewater influent
shall not exceed the manufacturer's design specifications for BOD5 loading as
established by NSF International or a laboratory approved by ANSI to determine
compliance with NSF International/ANSI Standard 40 during testing of the
plant.
3) Hourly flows from the
wastewater source into the plant are less than or equal to the treatment
capacity of the plant divided by 24. This may require the installation of a
flow equalization device.
4) A
buried sand filter sized with a surface area equal to 2 gallons per square foot
per day and dosed at least once but not more than 4 times per day shall
immediately follow the aerobic treatment plant.
k) Splitting of Flows. Splitting of flows
from a wastewater source or the use of multiple aerobic treatment plants or NSF
International/ANSI Standard 40 wastewater treatment systems shall be prohibited
unless subsurface disposal of the effluent is used. Where allowed, splitting of
flows shall be done by pumps.
l)
Private sewage disposal installation contractors or homeowners who maintain or
service aerobic treatment plants and NSF International/ANSI Standard 40
wastewater treatment systems shall be required to maintain the integrity of the
NSF International seal or the seal of a laboratory approved by ANSI to
determine compliance with NSF International/ANSI Standard 40. Only component
parts approved for use in an individual plant may be used. No design changes or
component part changes may be made that will void the NSF International seal or
the seal of a laboratory approved by ANSI to determine compliance with NSF
International/ANSI Standard 40. Any person who voids the NSF International seal
or the seal of a laboratory approved by ANSI to determine compliance with NSF
International/ANSI Standard 40 shall be responsible for repairing the plant so
it can bear the NSF International seal or the seal of a laboratory approved by
ANSI to determine compliance with NSF International/ANSI Standard 40 or shall
replace the plant with an approved private sewage disposal system.