Ohio Admin. Code 3745-256-100 - Applicability- containment buildings
Rules 3745-256-100 to 3745-256-102 of the Administrative Code apply to owners or operators who store or treat hazardous waste in units designed and operated under rule 3745-256-101 of the Administrative Code. The owner or operator is not subject to the definition of "land disposal" in rule 3745-270-02 of the Administrative Code provided that the unit:
(A) Is a completely enclosed, self-supporting
structure that is designed and constructed of man-made materials of sufficient
strength and thickness to support the materials, the waste contents, and any
personnel and heavy equipment that operate within the unit, and to prevent
failure due to pressure gradients, settlement, compression, uplift, physical
contact with the hazardous wastes to which the materials are exposed, climatic
conditions, and the stresses of daily operation (including the movement of
heavy equipment within the unit and contact of such equipment with containment
walls).
(B) Has a primary barrier
that is designed to be sufficiently durable to withstand the movement of
personnel and handling equipment within the unit.
(C) If used to manage a hazardous waste
containing free liquids (the presence of which is determined by the paint
filter test, a visual examination, or other appropriate means), has all of the
following:
(1) A primary barrier designed and
constructed of materials to prevent migration of hazardous constituents into
the barrier.
(2) A liquid
collection system designed and constructed of materials to minimize the
accumulation of liquid on the primary barrier.
(3) A secondary containment system designed
and constructed of materials to prevent migration of hazardous constituents
into the barrier, with a leak detection and liquid collection system capable of
detecting, collecting, and removing leaks of hazardous constituents at the
earliest possible time, unless the unit has
been
was granted a variance from the
secondary containment system requirements under paragraph (B)(4) of rule
3745-256-101
of the Administrative Code.
(D) Has controls as needed to prevent
fugitive dust emissions to meet the no visible emission standard in paragraph
(C)(1)(d) of rule
3745-256-101
of the Administrative Code.
(E) Is
designed and operated to ensure containment and prevent the tracking of
materials from the unit by personnel or equipment.
Notes
Promulgated Under: 119.03
Statutory Authority: 3734.12
Rule Amplifies: 3734.12
Prior Effective Dates: 12/07/2000, 12/07/2004, 02/16/2009, 10/31/2015
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.