(A) General requirements. Laboratories
applying for certification to perform analyses to determine compliance with
Chapters 3745-81, 3745-82 and 3745-90, and rules
3745-91-06 and 3745-9-09, and as
specified by paragraph (B) of rule
3745-83-01 of the Administrative
Code, and with plant control tests for one or more public water systems, shall
meet the following:
(1) The laboratory shall
submit, for approval by the director, a detailed laboratory plan which includes
the following:
(a) The analyses for which
certification is sought and the number of individuals proposed to perform each
analysis.
(b) Plans meeting the
facility requirements as defined in the "Ohio EPA Laboratory Manual for the
Microbiological Analyses of Public Drinking Water 2020
2025" and the
"Ohio EPA Laboratory Manual for the Chemical Analyses of Public Drinking Water
2020
2025."
(c)
The equipment proposed to be used in the laboratory, including specifications
or names, descriptions, manufacturers, and model numbers for each type of
equipment.
(d) The inventory of
standards, reagents and media to be used in analyses for which certification is
sought.
(2) The
laboratory shall submit a quality assurance plan acceptable to the director
when certification is sought for drinking water analysis. The "Ohio EPA
Laboratory Manual for the Microbiological Analyses of Public Drinking Water
2020
2025" and
the "Ohio EPA Laboratory Manual for the Chemical Analyses of Public Drinking
Water
2020
2025" may be used by laboratories seeking
certification for plant control and microbiological testing. Otherwise, an
acceptable quality assurance plan shall be developed by the laboratory as
described in the United States environmental protection agency's "Manual for
the Certification of Laboratories Analyzing Drinking Water" fifth edition,
dated January 2005 (designated "EPA 815-R-05-004"), as supplemented in both
June 2008 (designated "EPA 815-F-08-006") and November 2012 (designated "EPA
815-F-12-006") by "the United States Environmental Protection Agency, Office of
Ground Water and Drinking Water, Cincinnati, OH 45268." The quality assurance
plan shall include at least the following parts:
(a) Table of laboratory organization which
delineates the responsibilities of all laboratory personnel associated with
drinking water analyses and designates the individuals responsible for quality
assurance of drinking water analyses in the laboratory.
(b) Standard operating procedures including
identification of the reference methods used to perform the drinking water
analyses approved by the United States environmental protection
agency.
(c) Sample handling
procedures, including the following:
(i)
Instructions for maintaining the integrity of the samples by tracking samples
from collection to receipt, and, testing to disposal.
(ii) Instructions for sample preservation,
dechlorination, etc., as required by the
reference method and the documentation used by the laboratory to verify that
proper sample treatment is done.
(iii) Instructions to ensure that adequate
sample information is obtained to allow the proper analysis and reporting of
results.
(iv) Chain of custody
forms, where applicable.
(v)
Instructions for rejecting samples that do not meet shipping requirements,
required reporting information, holding time or preservation requirements and
instructions for notifying a public water system which submitted a sample that
is rejected for failing to meet minimum requirements.
(d) Routine practices to maintain the
precision and accuracy of data as specified by the director or required by each
method of analysis.
(e) Corrective
action procedures taken when unacceptable results are obtained from the
analysis of performance evaluation samples or quality control checks.
(f) Preventive maintenance procedures
including directions and scheduling for instrumentation servicing.
(g) Documentation of the preparation and
expiration of drinking water standards and reagents.
(h) Reporting procedures including directions
followed to ensure that reporting is completed as specified in rule
3745-89-08 of the Administrative
Code.
(3) The laboratory
shall submit to the director an application for certification for drinking
water analyses required of public water systems, on a form provided by the
director
. The application shall include the
following parts
, that includes the
following:
(a) The name, address and
telephone number of the laboratory and of the individuals responsible for the
laboratory.
(b) A list of analyses
for which certification is sought. This list shall designate which analytical
methods in rule
3745-81-27 or
3745-90-04 of the Administrative
Code shall be used for each analysis and shall include the name of each
individual who shall perform each analysis.
(c) Documentation that the laboratory plan in
paragraph (A)(1) of this rule has been accepted by the director.
(d) Documentation that the laboratory has
obtained acceptable results
according to the "National
Environmental Laboratory Accreditation Program" (NELAP) drinking water fields
of proficiency testing concentration range and acceptance criteria, located
at
https://www.nelac-institute.org/content/NEPTP/fopt.php
, and as described in paragraph (B) of this rule
,
for analyses performed on
all appropriate proficiency test samples provided by a proficiency
testing provider accredited by a provider of PT samples
accredited by a proficiency testing provider
accreditor meeting
the "National
Environmental Laboratory Accreditation Program requirement
(NELAP)"
NELAP requirements, and
documentation that proficiency test samples were analyzed at least annually for
every contaminant by each method for which the laboratory desires
certification. The director may designate other acceptable providers of
proficiency test samples for analyses to meet this requirement.
(e) Payment of the appropriate laboratory
survey fee established in accordance with section
3745.11 of the Revised Code.
Fees for these surveys shall be paid via a method acceptable to the director.
For the purposes of this rule, fees are as follows:
(i) The "organic chemicals" fee covers all
surveys necessary to obtain laboratory certification for the analysis of
drinking water for either of the following:
(a) Total trihalomethanes, haloacetic acids,
or volatile organic chemicals.
(b)
Pesticides and other organic chemicals.
(ii) The "trace metals" fee covers all
surveys necessary to obtain laboratory certification for the analysis of
drinking water for all metals identified by the United States environmental
protection agency as primary contaminants, secondary contaminants and
contaminants with action levels.
(iii) The "standard chemistry" fee covers all
surveys necessary to obtain laboratory certification for the analysis of
drinking water for bromate, chlorite, cyanide, fluoride, nitrate,
nitrate-nitrite, nitrite, orthophosphate, total phosphorus, sulfate, total
dissolved solids and plant control tests.
(iv) The "limited chemistry" fee covers all
surveys necessary to obtain laboratory certification for the analysis of
drinking water for the following:
(a) Any
three
two of
the analyses included in standard chemistry.
(b) Any two of the analyses included in trace
metals.
(c) Asbestos.
(d) Radioactivity and radioactive
chemicals.
(e)
Beginning one year from the effective date of this
rule, total
Total microcystins and
cyanobacteria screening.
(v) The "microbiological" fee covers all
surveys necessary to obtain laboratory certification for the analysis of
drinking water for
one of the following:
total coliform and E. coli.
(a)
MMO-MUG (Colilert or Colisure).
(b)
Membrane filtration (MF).
(c)
Most probable number (MPN) by MMO-MUG and
MF.
(4) The director shall return any application
which is not filed in accordance with paragraph (A)(3) of this rule.
(5) Upon the laboratory's successful
completion of the requirements of paragraphs (A)(1), (A)(2) and (A)(3) of this
rule, the laboratory shall demonstrate acceptable levels of performance during
the initial and subsequent
on-site surveys,
including the following:
(a) Conformance by
the laboratory to the "Ohio EPA Laboratory Manual for the Microbiological
Analyses of Public Drinking Water 2020
2025" and the "Ohio EPA Laboratory Manual for the
Chemical Analyses of Public Drinking Water 2020
2025."
(b) Proficiency in appropriate analytical
procedures, methodologies, techniques, and use of equipment by analysts
participating in the on-site
survey.
(c) Analysis of proficiency
test samples.
(d) Maintenance of
laboratory records for at least thirty days prior to the scheduled
on-site survey, with the records
documenting the following:
(i) All appropriate
laboratory equipment and auxiliary equipment is operational within prescribed
limits.
(ii) Sufficient practice
analyses have been conducted by each analyst participating in the
on-site survey to demonstrate the analyst's
proficiency.
(iii) An acceptable
quality assurance plan has been documented and implemented, as required by
paragraph (A)(2) of this rule.
(iv)
The analyses, quality control procedures, and preparation of standards were
correctly performed by each analyst participating in the
on-site survey, as required for the
certification being requested.
(v)
Acceptable method detection limit studies have been completed as required by
the director for each method and instrument in accordance with the procedures
in the 40 Code of Federal Regulations (C.F.R.) Part 136.
(e) The laboratory conforms to the laboratory
plan as approved by the director.
(f) The laboratory is able to meet the
analytical reporting limits listed in tables 1, 2, 3, 4, 5 and 5
6 in the appendix to this rule. Laboratories shall
report to the minimum level that they can consistently quantify but shall not
have a minimum reporting limit any higher than the level in the appendix to
this rule. Unless stated in this rule, the detection limits listed and defined
in Chapter 3745-81 of the Administrative Code shall also be used as reporting
limits.
(g) Correction of
violations noted in previous survey reports.
(6) The survey report shall be issued to the
applicant by the
Ohio environmental
protection agency within forty-five days of any
on-site survey,
shall indicate
indicating the acceptability of the applicant's
performance during the survey, and
shall
state
stating violations that are
required to be corrected prior to certification of the laboratory. If the
survey report notes violations the director may deny, suspend, or revoke
certification in accordance with rule
3745-89-06 of the Administrative
Code.
(B) Specific
requirements for proficiency testing (PT). Laboratories applying for
certification to perform drinking water analyses to determine compliance with
Chapters 3745-81 and 3745-82, rules
3745-91-06 and 3745-9-09, and as
specified by paragraph (B) of rule
3745-83-01 of the Administrative
Code, as well as plant control tests shall, in addition to the requirements of
paragraph (A) of this rule, include with the application the appropriate
required reports as follows:
(1) Applicants
for laboratory certification for analytes referenced in paragraphs
(C)
(B) to
(K)
(J) of
rule
3745-81-27 of the Administrative
Code
(except as otherwise noted) shall report PT
results in accordance with paragraph (A)(3)(d) of this rule with no
unacceptable results.
(2) Total
trihalomethanes. Applicants for laboratory certification to perform analyses
for
analytes
the
analyte group to determine compliance with rules
3745-81-12 and
3745-81-24 of the Administrative
Code shall report bromodichloromethane, bromoform, chloroform and
dibromochloromethane analysis in accordance with paragraph (A)(3)(d) of this
rule with no unacceptable results. Total trihalomethanes analysis requires
reporting all of the compounds established in the definition of total
trihalomethanes in rule
3745-81-01 of the Administrative
Code.
(3) Volatile organic
chemicals. Applicants for laboratory certification for
analytes
the analyte
group referenced in rules
3745-81-12 and
3745-81-24 of the Administrative
Code shall report PT analyses for volatile organic chemicals with maximum
contaminant levels (except vinyl chloride) in accordance with paragraph
(A)(3)(d) of this rule, with not more than twenty per cent unacceptable
results.
(4)
Vinyl chloride. Applicants for laboratory certification
for vinyl chloride shall hold laboratory certification for the twenty regulated
volatile organic chemicals listed in paragraph (C) of rule
3745-81-12 of the Administrative
Code and report PT analysis for this analyte in accordance with paragraph
(A)(3)(d) of this rule with no unacceptable results.
(4)(5)
Microbiological contaminants. Applicants for laboratory certification to
perform analyses for analytes to determine compliance with rules
3745-81-14
3745-81-51, 3745-81-21
3745-81-52,
and 3745-81-41 to 3745-81-45 of the Administrative Code shall report
microbiological contaminants analyses in accordance with paragraph (A)(3)(d) of
this rule with no more than one unacceptable total coliform result, no more
than one unacceptable E. coli result, and no false negative reported
values.
(5)(6) Haloacetic acids
(five). Applicants for laboratory certification to perform analyses for
analytes
the
analyte group to determine compliance with rules
3745-81-12 and
3745-81-24 of the Administrative
Code shall report haloacetic acids (five) analysis in accordance with paragraph
(A)(3)(d) of this rule with no more than one unacceptable result. Haloacetic
acids (five) analysis requires reporting all of the compounds listed in the
definition of haloacetic acids (five) in rule
3745-81-01 of the Administrative
Code.
(C) The director
may issue, deny, suspend or revoke a laboratory certificate in accordance with
rule
3745-89-06 of the Administrative
Code.
[Comment: This rule incorporates the "Ohio EPA Laboratory
Manual for the Microbiological Analyses of Drinking Water
2020
2025" and
"Ohio EPA Laboratory Manual for the Chemical Analyses of Public Drinking Water
2020
2025" by
reference. Copies are available at www.epa.ohio.gov/ddagw/labcert.aspxhttps://epa.ohio.gov/divisions-and-offices/drinking-and-ground-waters/public-water-systems/laboratory-certification
and at the "Ohio EPA, Lazarus Government Center, 50 West Town Street, Suite
700, Columbus, OH, 43215." Copies can also be obtained by contacting the
laboratory certification office at 614-644-4245
4222.]
[Comment: This rule incorporates the United States
environmental protection agency's "Manual for Certification of Laboratories
Analyzing Drinking Water" fifth edition, dated January 2005 (designated "EPA
815-R-05-004"), as supplemented in both June 2008 (designated "EPA
815-F-08-006") and November 2012 (designated "EPA 815-F-12-006) by the United
States environmental protection agency, office of ground water and drinking
water, Cincinnati, OH 45268 by reference. Copies are available at
http://www.epa.gov/dwlabcert
and also at the "Water Resource Center (RC-4100), United States Environmental
Protection Agency, 1200 Pennsylvania Avenue NW, Washington, D.C., 20460, (202)
566-1729." Copies can also be obtained by contacting the "Safe Drinking Water
Hotline" at 1-800-426-4791. This document is available for review at "Ohio EPA,
Lazarus Government Center, 50 West Town Street, Suite 700, Columbus, OH,
43215."]
Click to