(1)
General requirements.
Note to
437-002-2315: For employers
engaged in construction activities, mechanical equipment must be operated in
accordance with applicable requirements in Division 3, including subdivisions
N, O, and CC of Division 3, except that 1926.600(a)(6) does not apply to
operations performed by qualified employees.
(a) The critical safety components of
mechanical elevating and rotating equipment must receive a thorough visual
inspection before use on each shift.
Note to paragraph (1)(a): Critical safety
components of mechanical elevating and rotating equipment are components for
which failure would result in free fall or free rotation of the boom.
(b) No motor vehicle or
earthmoving or compacting equipment having an obstructed view to the rear may
be operated on off-highway jobsites where any employee is exposed to the
hazards created by the moving vehicle, unless:
(A) The vehicle has a reverse signal alarm
audible above the surrounding noise level, or
(B) The vehicle is backed up only when a
designated employee signals that it is safe to do so.
(c) Rubber-tired self-propelled scrapers,
rubber-tired front-end loaders, rubber-tired dozers, wheel-type agricultural
and industrial tractors, crawler-type tractors, crawler-type loaders, and motor
graders, with or without attachments, must have rollover protective structures
that meet the requirements of Division 3/W.
(d) The operator of an electric line truck
may not leave their position at the controls while a load is suspended, unless
the employer can demonstrate that no employee (including the operator) is
endangered.
(2)
Outriggers.
(a) Mobile equipment, if provided
with outriggers, must be operated with the outriggers extended and firmly set,
except as provided in paragraph (2)(c) of this rule.
(b) Outriggers may not be extended or
retracted outside of the clear view of the operator unless all employees are
outside the range of possible equipment motion.
(c) If the work area or the terrain precludes
the use of outriggers, the equipment may be operated only within its maximum
load ratings specified by the equipment manufacturer for the particular
configuration of the equipment without outriggers.
(3) Applied loads. Mechanical equipment used
to lift or move lines or other material must be used within its maximum load
rating and other design limitations for the conditions under which the
mechanical equipment is being used.
(4) Operations near energized lines or
equipment.
(a) Mechanical equipment must be
operated so that the minimum approach distances from exposed energized lines
and equipment, established by the employer under paragraph (3)(a) of
437-002-2311, are maintained.
However, the insulated portion of an aerial lift operated by a qualified
employee in the lift is exempt from this requirement if the applicable minimum
approach distance is maintained between the uninsulated portions of the aerial
lift and exposed objects having a different electrical potential.
(b) A designated employee other than the
equipment operator must observe the approach distance to exposed lines and
equipment and provide timely warnings before the minimum approach distance
required by paragraph (4)(a) of this rule is reached, unless the employer can
demonstrate that the operator can accurately maintain the minimum approach
distance.
(c) Aerial lifts must
have dual controls (lower and upper) as follows:
(A) The upper controls must be within easy
reach of the employee in the bucket. On a two-bucket-type lift, access to the
controls must be within easy reach of both buckets.
(B) The lower set of controls must be near
the base of the boom and must be designed so that they can override operation
of the equipment at any time.
(C)
Controls must be placed and guarded so that the equipment cannot be activated
by inadvertent contact by the operator, tools, equipment, lines, or foreign
objects.
(d) If, during
operation of the mechanical equipment, that equipment could become energized,
the operation also must comply with at least one of paragraphs (4)(d)(A)
through (4)(d)(C) of this rule.
(A) The
energized lines or equipment exposed to contact must be covered with insulating
protective material that will withstand the type of contact that could be made
during the operation.
(B) The
mechanical equipment must be insulated for the voltage involved. The mechanical
equipment must be positioned so that its uninsulated portions cannot approach
the energized lines or equipment any closer than the minimum approach
distances, established by the employer under paragraph (3)(a) of
437-002-2311.
(C) Each employee must be protected from
hazards that could arise from mechanical equipment contact with energized lines
or equipment. The measures used must ensure that employees will not be exposed
to hazardous differences in electric potential. Unless the employer can
demonstrate that the methods in use protect each employee from the hazards that
could arise if the mechanical equipment contacts the energized line or
equipment, the measures used must include all of the following techniques:
(i) Using the best available ground to
minimize the time the lines or electric equipment remain energized,
(ii) Bonding mechanical equipment together to
minimize potential differences,
(iii) Providing ground mats to extend areas
of equipotential, and
(iv)
Employing insulating protective equipment or barricades to guard against any
remaining hazardous electrical potential differences.
Note to paragraph (4)(d)(C): Appendix C to
Division 2/RR contains information on hazardous step and touch potentials and
on methods of protecting employees from hazards resulting from such
potentials.