(a)
Applicability. This section applies to the owner or operator
of each control device that receives a liquid, gas, vapor or fume from a source
subject to §
129.123(b)(1)(iii),
§
129.125(b)(1)(ii) or
(c)(1), or §
129.126(b)(2) or
(c)(2) (relating to storage vessels; natural
gas-driven diaphragm pumps; and compressors).
(1) The owner or operator shall perform the
following:
(i) Operate each control device
whenever a liquid, gas, vapor or fume is routed to the control
device.
(ii) Maintain the records
under §
129.130(j)
(relating to recordkeeping and reporting) and submit the reports under §
129.130(k)(3)(ix).
(2) The owner or operator may route the
liquid, gas, vapor or fume from more than one source subject to §
129.123(b)(1)(iii),
§
129.125(b)(1)(ii) or
(c)(1), or §
129.126(b)(2) or
(c)(2) to a control device installed and
operated under this section.
(b)
General requirements for a
control device. The owner or operator of a control device subject to
this section shall install and operate one or more control devices listed in
subsections (c)-(i). The owner or operator shall meet the following
requirements, as applicable:
(1) Operate the
control device following the manufacturer's written operating instructions,
procedures and maintenance schedule to ensure good air pollution control
practices for minimizing VOC emissions.
(2) Ensure that the control device is
maintained in a leak-free condition by conducting a physical integrity check
according to the manufacturer's instructions, with monthly inspections
separated by at least 15 calendar days but not more than 45 calendar
days.
(3) Maintain a pilot flame
while operating the control device and monitor the pilot flame by installing a
heat sensing CPMS as specified under subsection (m)(3). If the heat sensing
CPMS indicates the absence of the pilot flame or if the control device is
smoking or shows other signs of improper equipment operation, ensure the
control device is returned to proper operation by performing the following
procedures:
(i) Checking the air vent for
obstruction and clearing an observed obstruction.
(ii) Checking for liquid reaching the
combustor.
(4) Operate
the control device with no visible emissions, except for periods not to exceed
a total of 1 minute during a 15-minute period as determined by conducting a
visible emissions test according to Section 11 of EPA Method 22.
(i) Each monthly visible emissions test shall
be separated by at least 15 calendar days but not more than 45 calendar
days.
(ii) The observation period
for the test in subparagraph (i) shall be 15 minutes.
(5) Repair the control device if it fails the
visible emissions test of paragraph (4) as specified in subparagraph (i) or
subparagraph (ii) and return the control device to compliant operation.
(i) The manufacturer's repair instructions,
if available.
(ii) The best
combustion engineering practice applicable to the control device if the
manufacturer's repair instructions are not available.
(6) Ensure the control device passes the EPA
Method 22 visual emissions test described in paragraph (4) following return to
operation from a maintenance or repair activity.
(7) Record the inspection, repair and
maintenance activities for the control device in a maintenance and repair
log.
(c)
Compliance requirements for a manufacturer-tested combustion
device. The owner or operator of a control device subject to this
section that installs a control device tested under
40 CFR
60.5413a(d) (relating to
what are the performance testing procedures for control devices used to
demonstrate compliance at my centrifugal compressor and storage vessel affected
facilities?) shall meet subsection (b)(1)- (7) and the following:
(1) Maintain the inlet gas flow rate at less
than or equal to the maximum flow rate specified by the manufacturer. This is
confirmed by one of the following:
(i)
Installing, operating and maintaining a flow CPMS that meets subsection (m)(1)
and (2)(i) to measure gas flow rate at the inlet to the control
device.
(ii) Conducting a periodic
performance test under subsection (k) instead of installing a flow CPMS to
demonstrate that the mass content of VOC in the gases vented to the device is
reduced by 95.0% by weight or greater.
(2) Submit an electronic copy of the
performance test results to the EPA as required by
40 CFR
60.5413a(d) in accordance
with 40 CFR
60.5413a(e)(6).
(d)
Compliance requirements for an
enclosed combustion device. The owner or operator of a control device
subject to this section that installs an enclosed combustion device, such as a
thermal vapor incinerator, catalytic vapor incinerator, boiler or process
heater, shall meet subsection (b)(1)- (7) and the following:
(1) Ensure the enclosed combustion control
device is designed and operated to meet one of the following performance
requirements:
(i) To reduce the mass content
of VOC in the gases vented to the device by 95.0% by weight or greater, as
determined under subsection (k).
(ii) To reduce the concentration of TOC in
the exhaust gases at the outlet to the device to a level less than or equal to
275 ppmvd as propane corrected to 3% oxygen as determined under subsection
(l).
(iii) To operate at a minimum
temperature of 760 °Celsius (1,400 °Fahrenheit), if it is demonstrated
during the performance test conducted under subsection (k) that combustion zone
temperature is an indicator of destruction efficiency.
(iv) To introduce the vent stream into the
flame zone of the boiler or process heater if a boiler or process heater is
used as the control device.
(2) Install, calibrate, operate and maintain
a CPMS according to the manufacturer's specifications and subsection (m) to
measure the values of the operating parameters appropriate to the control
device as follows:
(i) For a thermal vapor
incinerator that demonstrates under subsection (m)(6)(i) that combustion zone
temperature is an accurate indicator of performance, a temperature CPMS that
meets subsection (m)(1) and (4) with the temperature sensor installed at a
location representative of the combustion zone temperature.
(ii) For a catalytic vapor incinerator, a
temperature CPMS capable of monitoring temperature at two locations and that
meets subsection (m)(1) and (4) with one temperature sensor installed in the
vent stream at the nearest feasible point to the catalyst bed inlet and a
second temperature sensor installed in the vent stream at the nearest feasible
point to the catalyst bed outlet.
(iii) For a boiler or process heater that
demonstrates under subsection (m)(6)(i) that combustion zone temperature is an
accurate indicator of performance, a temperature CPMS that meets subsection
(m)(1) and (4) with the temperature sensor installed at a location
representative of the combustion zone temperature. The monitoring requirements
do not apply if the boiler or process heater meets either of the following:
(A) Has a design heat input capacity of 44
megawatts (150 MMBtu per hour) or greater.
(B) Introduces the vent stream with the
primary fuel or uses the vent stream as the primary fuel.
(iv) For a control device complying with
paragraph (1)(ii), an organic concentration CPMS that meets subsection (m)(1)
and (5) that measures the concentration level of organic compounds in the
exhaust vent stream from the control device.
(3) Operate the control device in compliance
with the operating parameter value established under subsection
(m)(6).
(4) Calculate the daily
average of the monitored operating parameter for each operating day, using the
valid data recorded by the monitoring system under subsection (m)(7).
(5) Ensure that the daily average of the
monitoring parameter value calculated under paragraph (4) complies with the
parameter value established under paragraph (3) as specified in subsection
(m)(9).
(6) Operate the CPMS
installed under paragraph (2) whenever the source is operating, except during
the times specified in subsection (m)(8)(iii).
(e)
Compliance requirements for a
flare. The owner or operator of a control device subject to this
section that installs a flare designed and operated in accordance with
40 CFR
60.18(b) (relating to
general control device and work practice requirements) shall meet subsection
(b)(3)- (7).
(f)
Compliance
requirements for a carbon adsorption system. The owner or operator of
a control device subject to this section that installs a carbon adsorption
system shall meet subsection (b)(1) and (2) and the following:
(1) Design and operate the carbon adsorption
system to reduce the mass content of VOC in the gases vented to the device as
demonstrated by one of the following:
(i)
Determining the VOC emission reduction is 95.0% by weight or greater as
specified in subsection (k).
(ii)
Reducing the concentration of TOC in the exhaust gases at the outlet to the
device to a level less than or equal to 275 ppmvd as propane corrected to 3%
oxygen as determined under subsection (l).
(iii) Conducting a design analysis in
accordance with subsection (g)(6) or subsection (h)(2) as applicable.
(2) Include a carbon replacement
schedule in the design of the carbon adsorption system.
(3) Replace the carbon in the control device
with fresh carbon on a regular schedule that is no longer than the carbon
service life established according to the design analysis in subsection (g)(6)
or subsection (h)(2) or according to the replacement schedule in paragraph
(2).
(4) Manage the spent carbon
removed from the carbon adsorption system in paragraph (3) by one of the
following:
(i) Regenerating or reactivating
the spent carbon in one of the following:
(A)
A thermal treatment unit for which the owner or operator has been issued a
permit under 40 CFR Part
270 (relating to EPA administered permit programs: the
hazardous waste permit program) that implements the requirements of 40 CFR Part
264, Subpart X (relating to miscellaneous units).
(B) A unit equipped with operating organic
air emission controls in accordance with an emissions standard for VOC under a
subpart in 40 CFR Part
60 (relating to standards of performance for new
stationary sources) or 40 CFR Part
63 (relating to National emission standards
for hazardous air pollutants for source categories).
(ii) Burning the spent carbon in one of the
following:
(A) A hazardous waste incinerator,
boiler or industrial furnace for which the owner or operator complies with the
requirements of 40 CFR Part
63, Subpart EEE (relating to National emission
standards for hazardous air pollutants from hazardous waste combustors) and has
submitted a Notification of Compliance under
40 CFR
63.1207(j) (relating to what
are the performance testing requirements?).
(B) An industrial furnace for which the owner
or operator has been issued a permit under 40 CFR Part
270 that implements the
requirements of 40 CFR Part
266, Subpart H (relating to hazardous waste burned
in boilers and industrial furnaces).
(C) An industrial furnace designed and
operated in accordance with the interim status requirements of 40 CFR Part
266,
Subpart H.
(g)
Additional compliance
requirements for a regenerative carbon adsorption system. The owner or
operator of a control device subject to this section that installs a
regenerative carbon adsorption system shall meet subsection (f) and the
following:
(1) Install, calibrate, operate and
maintain a CPMS according to the manufacturer's specifications and the
applicable requirements of subsection (m) to measure the values of the
operating parameters appropriate to the control device as follows:
(i) For a source complying with subsection
(f)(1)(i), a flow CPMS system that meets the requirements of subsection (m)(1)
and (2)(ii) to measure and record the average total regeneration steam mass
flow or volumetric flow during each carbon bed regeneration cycle. The owner or
operator shall inspect the following:
(A) The
mechanical connections for leakage with monthly inspections separated by at
least 15 calendar days but not more than 45 calendar days.
(B) The components of the flow CPMS for
physical and operational integrity if the flow CPMS is not equipped with a
redundant flow sensor with quarterly inspections separated by at least 60
calendar days but not more than 120 calendar days.
(C) The electrical connections of the flow
CPMS for oxidation and galvanic corrosion if the flow CPMS is not equipped with
a redundant flow sensor with quarterly inspections separated by at least 60
calendar days but not more than 120 calendar days.
(ii) For a source complying with subsection
(f)(1)(i), a temperature CPMS that meets the requirements of subsection (m)(1)
and (4) to measure and record the average carbon bed temperature for the
duration of the carbon bed steaming cycle and measure the actual carbon bed
temperature after regeneration and within 15 minutes of completing the cooling
cycle.
(iii) For a source complying
with subsection (f)(1)(ii), an organic concentration CPMS that meets subsection
(m)(1) and (5) that measures the concentration level of organic compounds in
the exhaust vent stream from the control device.
(2) Operate the control device in compliance
with the operating parameter value established under subsection
(m)(6).
(3) Calculate the daily
average of the applicable monitored operating parameter for each operating day,
using the valid data recorded by the CPMS as specified in subsection
(m)(7).
(4) Ensure that the daily
average of the monitoring parameter value calculated under paragraph (3)
complies with the parameter value established under paragraph (2) as specified
in subsection (m)(9).
(5) Operate
the CPMS installed in paragraph (1) whenever the source is operating, except
during the times specified in subsection (m)(8)(iii).
(6) Ensure that the design analysis to meet
subsection (f)(1)(iii) and (2) for the regenerable carbon adsorption system
meets the following:
(i) Includes an analysis
of the vent stream, including the following information:
(A) Composition.
(B) Constituent concentrations.
(C) Flowrate.
(D) Relative humidity.
(E) Temperature.
(ii) Establishes the following parameters for
the regenerable carbon adsorption system:
(A)
Design exhaust vent stream organic compound concentration level.
(B) Adsorption cycle time.
(C) Number and capacity of carbon
beds.
(D) Type and working capacity
of activated carbon used for the carbon beds.
(E) Design total regeneration stream flow
over the period of each complete carbon bed regeneration cycle.
(F) Design carbon bed temperature after
regeneration.
(G) Design carbon bed
regeneration time.
(H) Design
service life of the carbon.
(h)
Additional compliance
requirements for a non-regenerative carbon adsorption system. The
owner or operator of a control device subject to this section that installs a
non-regenerative carbon adsorption system shall meet subsection (f) and the
following:
(1) Monitor the design carbon
replacement interval established in subsection (f)(2) or paragraph (2). The
design carbon replacement interval must be based on the total carbon working
capacity of the control device and the source operating schedule.
(2) Ensure that the design analysis to meet
subsection (f)(1)(iii) and (2) for a non-regenerable carbon adsorption system,
such as a carbon canister, meets the following:
(i) Includes an analysis of the vent stream
including the following information:
(A)
Composition.
(B) Constituent
concentrations.
(C)
Flowrate.
(D) Relative
humidity.
(E)
Temperature.
(ii)
Establishes the following parameters for the non-regenerable carbon adsorption
system:
(A) Design exhaust vent stream organic
compound concentration level.
(B)
Capacity of the carbon bed.
(C)
Type and working capacity of activated carbon used for the carbon
bed.
(D) Design carbon replacement
interval based on the total carbon working capacity of the control device and
the source operating schedule.
(iii) Incorporates dual carbon canisters in
case of emission breakthrough occurring in one canister.
(i)
Compliance requirements
for a condenser or nondestructive control device. The owner or
operator of a control device subject to this section that installs a condenser
or other non-destructive control device shall meet subsection (b)(1) and (2)
and the following:
(1) Design and operate the
condenser or other nondestructive control device to reduce the mass content of
VOC in the gases vented to the device as demonstrated by one of the following:
(i) Determining the VOC emissions reduction
is 95.0% by weight or greater under subsection (k).
(ii) Reducing the concentration of TOC in the
exhaust gases at the outlet to the device to a level less than or equal to 275
ppmvd as propane corrected to 3% oxygen as determined under subsection
(l).
(iii) Conducting a design
analysis in accordance with paragraph (7).
(2) Prepare a site-specific monitoring plan
that addresses the following CPMS design, data collection, and quality
assurance and quality control elements:
(i)
The performance criteria and design specifications for the CPMS equipment,
including the following:
(A) The location of
the sampling interface that allows the CPMS to provide representative
measurements. For a temperature CPMS that meets the requirements of subsection
(m)(1) and (4) the sensor must be installed in the exhaust vent stream as
detailed in the procedures of the site-specific monitoring plan.
(B) Equipment performance checks, system
accuracy audits or other audit procedures.
(I)
Performance evaluations of each CPMS shall be conducted in accordance with the
site-specific monitoring plan.
(II)
CPMS performance checks, system accuracy audits or other audit procedures
specified in the site-specific monitoring plan shall be conducted at least once
every 12 months.
(ii) Ongoing operation and maintenance
procedures in accordance with
40 CFR
60.13(b) (relating to
monitoring requirements).
(iii)
Ongoing reporting and recordkeeping procedures in accordance with
40 CFR
60.7(c), (d) and (f)
(relating to notification and record keeping).
(3) Install, calibrate, operate and maintain
a CPMS according to the site-specific monitoring plan described in paragraph
(2) and the applicable requirements of subsection (m) to measure the values of
the operating parameters appropriate to the control device as follows:
(i) For a source complying with paragraph
(1)(i), a temperature CPMS that meets subsection (m)(1) and (4) to measure and
record the average condenser outlet temperature.
(ii) For a source complying with paragraph
(1)(ii), an organic concentration CPMS that meets subsection (m)(1) and (5)
that measures the concentration level of organic compounds in the exhaust vent
stream from the control device.
(4) Operate the control device in compliance
with the operating parameter value established under subsection
(m)(6).
(5) Calculate the daily
average of the applicable monitored operating parameter for each operating day,
using the valid data recorded by the CPMS as follows:
(i) For a source complying with paragraph
(1)(i), use the calculated daily average condenser outlet temperature as
specified in subsection (m)(7) and the condenser performance curve established
under subsection (m)(6)(iii) to determine the condenser efficiency for the
current operating day. Calculate the 365-day rolling average TOC emission
reduction, as appropriate, from the condenser efficiencies as follows:
(A) If there is less than 120 days of data
for determining average TOC emission reduction, calculate the average TOC
emission reduction for the first 120 days of operation. Compliance is
demonstrated with paragraph (1)(i) if the 120-day average TOC emission
reduction is equal to or greater than 95.0% by weight.
(B) After 120 days and no more than 364 days
of operation, calculate the average TOC emission reduction as the TOC emission
reduction averaged over the number of days of operation for which there is
data. Compliance is demonstrated with paragraph (1)(i) if the average TOC
emission reduction is equal to or greater than 95.0% by weight.
(C) If there is data for 365 days or more of
operation, compliance is demonstrated with the TOC emission reduction if the
rolling 365-day average TOC emission reduction calculated in subparagraph (i)
is equal to or greater than 95.0% by weight.
(ii) For a source complying with paragraph
(1)(ii), calculate the daily average concentration for each operating day,
using the data recorded by the CPMS as specified in subsection (m)(7).
Compliance is demonstrated with paragraph (1)(ii) if the daily average
concentration is less than the operating parameter under paragraph (4) as
specified in subsection (m)(9).
(6) Operate the CPMS installed in accordance
with paragraph (3) whenever the source is operating, except during the times
specified in subsection (m)(8)(iii).
(7) Ensure that the design analysis to meet
paragraph (1)(iii) for a condenser or other non-destructive control device
meets the following:
(i) Includes an analysis
of the vent stream including the following information:
(A) Composition.
(B) Constituent concentrations.
(C) Flowrate.
(D) Relative humidity.
(E) Temperature.
(ii) Establishes the following parameters for
the condenser or other non-destructive control device:
(A) Design outlet organic compound
concentration level.
(B) Design
average temperature of the condenser exhaust vent stream.
(C) Design average temperatures of the
coolant fluid at the condenser inlet and outlet.
(j)
General
performance test requirements. The owner or operator shall meet the
following performance test requirements:
(1)
The owner or operator shall do the following, as applicable:
(i) Except as specified in subparagraph
(iii), conduct an initial performance test within 180 days after installation
of a control device.
(ii) Except as
specified in subparagraph (iii), conduct a performance test of an existing
control device on or before August 7, 2023, unless the owner or operator of the
control device is complying with an established performance test interval, in
which case the current schedule should be maintained.
(iii) The performance test in subparagraph
(i) or subparagraph (ii) is not required if the owner or operator meets one or
more of the following:
(A) Installs a
manufacturer-tested combustion device that meets the requirements of subsection
(c).
(B) Installs a flare that
meets the requirements of subsection (e).
(C) Installs a boiler or process heater with
a design heat input capacity of 44 megawatts (150 MMBtu per hour) or
greater.
(D) Installs a boiler or
process heater which introduces the vent stream with the primary fuel or uses
the vent stream as the primary fuel.
(E) Installs a boiler or process heater which
burns hazardous waste that meets one or more of the following:
(I) For which an operating permit was issued
under 40 CFR Part
270 (relating to EPA administered permit programs: the
hazardous waste permit program) and complies with the requirements of 40 CFR
Part
266, Subpart H.
(II) For which
compliance with the interim status requirements of 40 CFR Part
266, Subpart H
has been certified.
(III) Which
complies with 40 CFR Part
63, Subpart EEE and for which a Notification of
Compliance under 40 CFR
63.1207(j) was submitted to
the Department.
(IV) Which complies
with 40 CFR Part
63, Subpart EEE and for which a Notification of Compliance
under 40 CFR
63.1207(j) will be submitted
to the Department within 90 days of the completion of the initial performance
test report unless a written request for an extension is submitted to the
Department.
(F) Installs
a hazardous waste incinerator which meets the requirements of 40 CFR Part
63,
Subpart EEE and for which the Notification of Compliance under
40 CFR
63.1207(j):
(I) Was submitted to the
Department.
(II) Will be submitted
to the Department within 90 days of the completion of the initial performance
test report unless a written request for an extension is submitted to the
Department.
(G) Requests
the performance test be waived under
40 CFR
60.8(b) (relating to
performance tests).
(2) Conduct a periodic performance test no
more than 60 months after the most recent performance test unless the owner or
operator:
(i) Monitors the inlet gas flow for
a manufacturer-tested combustion device under subsection (c)(1)(i).
(ii) Installs a control device exempt from
testing requirements under paragraph (1)(iii)(A)- (G).
(iii) Establishes a correlation between
firebox or combustion chamber temperature and the VOC performance level for an
enclosed combustion device under subsection (d)(2)(iii).
(3) Conduct a performance test when
establishing a new operating limit.
(k)
Performance test method for
demonstrating compliance with a control device weight-percent VOC emission
reduction requirement. Demonstrate compliance with the control device
weight-percent VOC emission reduction requirements of subsections (c)(1)(ii),
(d)(1)(i), (f)(1)(i) and (i)(1)(i) by meeting subsection (j) and the following:
(1) Conducting a minimum of three test runs
of at least 1-hour duration.
(2)
Using EPA Method 1 or EPA Method 1A, as appropriate, to select the sampling
sites which must be located at the inlet of the first control device and at the
outlet of the final control device. References to particulate mentioned in EPA
Method 1 or EPA Method 1A do not apply to this paragraph.
(3) Using EPA Method 2, EPA Method 2A, EPA
Method 2C or EPA Method 2D, as appropriate, to determine the gas volumetric
flowrate.
(4) Using EPA Method 25A
to determine compliance with the control device percent VOC emission reduction
performance requirement using the following procedure:
(i) Convert the EPA Method 25A results to a
dry basis, using EPA Method 4.
(ii)
Compute the mass rate of TOC using the following equations:
Click to view image
Where:
Ei = Mass rate
of TOC at the inlet of the control device on a dry basis, in kilograms per hour
(pounds per hour).
Eo = Mass rate
of TOC at the outlet of the control device on a dry basis, in kilograms per
hour (pounds per hour).
K2 = Constant,
2.494 * 10-6 (ppm) (mole per standard cubic meter)
(kilogram per gram) (minute per hour) where standard temperature (mole per
standard cubic meter) is 20 °Celsius.
Or
K2 = Constant,
1.554 * 10-7 (ppm) (lb-mole per standard cubic feet)
(minute per hour), where standard temperature (lb-mole per standard cubic feet)
is 68 °Fahrenheit.
Ci =
Concentration of TOC, as propane, of the gas stream as measured by EPA Method
25A at the inlet of the control device, ppmvd.
Co =
Concentration of TOC, as propane, of the gas stream as measured by EPA Method
25A at the outlet of the control device, ppmvd.
Mp = Molecular
weight of propane, 44.1 gram per mole (pounds per lb-mole).
Qi = Flowrate
of gas stream at the inlet of the control device in dry standard cubic meter
per minute (dry standard cubic feet per minute).
Qo = Flowrate
of gas stream at the outlet of the control device in dry standard cubic meter
per minute (dry standard cubic feet per minute).
(iii) Calculate the percent reduction in TOC
as follows:
Click to view image
Where:
Rcd = Control
efficiency of control device, percent.
Ei = Mass rate
of TOC at the inlet to the control device as calculated in subparagraph (ii),
kilograms per hour (pounds per hour).
Eo = Mass rate
of TOC at the outlet of the control device as calculated in subparagraph (ii),
kilograms per hour (pounds per hour).
(iv) If the vent stream entering a boiler or
process heater with a performance testing requirement is introduced with the
combustion air or as a secondary fuel, the owner or operator shall:
(A) Calculate
Ei in subparagraph (ii) by using the
TOC concentration in all combusted vent streams, primary fuels and secondary
fuels as Ci.
(B) Calculate
Eo in subparagraph (ii) by using the
TOC concentration exiting the device as
Co.
(C) Determine the weight-percent reduction of
TOC across the device in accordance with subparagraph (iii).
(5) The weight-percent
reduction of TOC across the control device represents the VOC weight-percent
reduction for demonstration of compliance with subsections (c)(1)(ii),
(d)(1)(i), (f)(1)(i) and (i)(1)(i).
(l)
Performance test method for
demonstrating compliance with an outlet concentration requirement.
Demonstrate compliance with the TOC concentration requirement of subsections
(d)(1)(ii), (f)(1)(ii) and (i)(1)(ii) by meeting subsection (j) and the
following:
(1) Conducting a minimum of three
test runs of at least 1-hour duration.
(2) Using EPA Method 1 or EPA Method 1A, as
appropriate, to select the sampling sites which must be located at the outlet
of the control device. References to particulate mentioned in EPA Method 1 or
EPA Method 1A do not apply to this paragraph.
(3) Using EPA Method 2, EPA Method 2A, EPA
Method 2C, or EPA Method 2D, as appropriate, to determine the gas volumetric
flowrate.
(4) Using EPA Method 25A
to determine compliance with the TOC concentration requirement using the
following procedures:
(i) Measure the TOC
concentration, as propane.
(ii) For
a control device subject to subsection (f) or subsection (i), the results of
EPA Method 25A in subparagraph (i) may be adjusted by subtracting the
concentration of methane and ethane measured using EPA Method 18 taking either:
(A) An integrated sample.
(B) A minimum of four grab samples per hour
using the following procedures:
(I) Taking the
samples at approximately equal intervals in time, such as 15-minute intervals
during the run.
(II) Taking the
samples during the same time as the EPA Method 25A sample.
(III) Determining the average methane and
ethane concentration per run.
(iii) The TOC concentration must be adjusted
to a dry basis, using EPA Method 4.
(iv) The TOC concentration must be corrected
to 3% oxygen as follows:
(A) The oxygen
concentration must be determined using the emission rate correction factor for
excess air, integrated sampling and analysis procedures from one of the
following methods:
(I) EPA Method
3A.
(II) EPA Method 3B.
(III) ASTM D6522-00.
(IV) ANSI/ASME PTC 19.10-1981, Part
10.
(B) The samples for
clause (A) must be taken during the same time that the samples are taken for
determining the TOC concentration.
(C) The TOC concentration for percent oxygen
must be corrected as follows:
Click to view image
Where:
Cc = TOC
concentration, as propane, corrected to 3% oxygen, ppmvd.
Cm = TOC
concentration, as propane, ppmvd.
%O2m =
Concentration of oxygen, percent by volume as measured, dry.
(m)
Continuous parameter monitoring system requirements. The owner
or operator of a source subject to §
129.121(a)
(relating to general provisions and applicability) and controlled by a device
listed in subsections (c)-(i) that is required to install a CPMS shall:
(1) Ensure the CPMS measures the applicable
parameter at least once every hour and continuously records either:
(i) The measured operating parameter
value.
(ii) The block average
operating parameter value for each 1-hour period calculated using the following
procedures:
(A) The block average from all
measured data values during each period.
(B) If values are measured more frequently
than once per minute, a single value for each minute may be used instead of all
measured values.
(2) Ensure the flow CPMS has either:
(i) An accuracy of ±2% or better at
the maximum expected flow rate.
(ii) A measurement sensitivity of 5% of the
flow rate or 10 standard cubic feet per minute, whichever is greater.
(3) Ensure the heat-sensing CPMS
indicates the presence of the pilot flame while emissions are routed to the
control device. Heat-sensing CPMS are exempt from the calibration, quality
assurance and quality control requirements in this section.
(4) Ensure the temperature CPMS has a minimum
accuracy of ±1% of the temperature being monitored in °Celsius
(±1.8% in °Fahrenheit) or ±2.5 °Celsius (±4.5
°Fahrenheit), whichever value is greater.
(5) Ensure the organic concentration CPMS
meets the requirements of Performance Specification 8 or 9 of 40 CFR Part
60,
Appendix B (relating to performance specifications).
(6) Establish the operating parameter value
to define the conditions at which the control device must be operated to
continuously achieve the applicable performance requirement as follows:
(i) For a parameter value established while
conducting a performance test under subsection (k) or subsection (l):
(A) Base each minimum operating parameter
value on the value established while conducting the performance test and
supplemented, as necessary, by the design analysis of subsection (g)(6),
subsection (h)(2) or subsection (i)(7), the manufacturer's recommendations, or
both.
(B) Base each maximum
operating parameter value on the value established while conducting the
performance test and supplemented, as necessary, by the design analysis of
subsection (g)(6), subsection (h)(2) or subsection (i)(7), the manufacturer's
recommendations, or both.
(ii) Except as specified in clause (C), for a
parameter value established using a design analysis in subsection (g)(6),
subsection (h)(2) or subsection (i)(7):
(A)
Base each minimum operating parameter value on the value established in the
design analysis and supplemented, as necessary, by the manufacturer's
recommendations.
(B) Base each
maximum operating parameter value on the value established in the design
analysis and supplemented, as necessary, by the manufacturer's
recommendations.
(C) If the owner
or operator and the Department do not agree on a demonstration of control
device performance using a design analysis as specified in clause (A) or (B),
then the owner or operator shall perform a performance test under subsection
(k) or subsection (l) to resolve the disagreement. The Department may choose to
have an authorized representative observe the performance test.
(iii) For a condenser, establish a
condenser performance curve showing the relationship between condenser outlet
temperature and condenser control efficiency that demonstrates the condenser
complies with the applicable performance requirements in subsection (i)(1) as
follows:
(A) Based on the value measured
while conducting a performance test under subsection (k) or subsection (l) and
supplemented, as necessary, by a condenser design analysis performed under
subsection (i)(7), the manufacturer's recommendations, or both.
(B) Based on the value from a condenser
design analysis performed under subsection (i)(7) supplemented, as necessary,
by the manufacturer's recommendations.
(7) Except for the CPMS in paragraphs (2) and
(3), calculate the daily average for each monitored parameter for each
operating day using the data recorded by the CPMS. Valid data points must be
available for 75% of the operating hours in an operating day to compute the
daily average where the operating day is:
(i)
A 24-hour period if the control device operation is continuous.
(ii) The total number of hours of control
device operation per 24-hour period.
(8) Except as specified in subparagraph
(iii), do both of the following:
(i) Ensure
the data recorded by the CPMS is used to assess the operation of the control
device and associated control system.
(ii) Report the failure to collect the
required data in paragraph (1) as a deviation of the monitoring
requirements.
(iii) The
requirements of subparagraphs (i) and (ii) do not apply during:
(A) A monitoring system
malfunction.
(B) A repair
associated with a monitoring system malfunction.
(C) A required monitoring system quality
assurance or quality control activity.
(9) Determine compliance with the established
parameter value by comparing the calculated daily average to the established
operating parameter value as follows:
(i) For
a minimum operating parameter established in paragraph (6)(i)(A) or paragraph
(6)(ii)(A), the control device is in compliance if the calculated value is
equal to or greater than the established value.
(ii) For a maximum operating parameter
established in paragraph (6)(i)(B) or paragraph (6)(ii)(B), the control device
is in compliance if the calculated value is less than or equal to the
established value.