Utah Admin. Code R307-316-4 - Requirements
(1) Except as provided in Subsection
R307-316-4(3), an owner or operator of a boiler subject to this rule shall:
(a) install a burner that meets a NOx
emission rate of nine parts per million by volume (ppmv) or less at 3% volume
stack gas oxygen on a dry basis; and
(b) meet a CO emission rate of 400 ppmv or
less at 3% volume stack gas oxygen on a dry basis.
(2) An owner or operator of a boiler subject
to Subsection R307-316-4(1) shall:
(a) operate
and maintain the boiler and boiler subsystems, including burners, according to
the manufacturer's instructions;
(b) determine continued compliance based on
Section R307-316-6; and
(c) ensure
that manufacturer's operational specifications, records, and testing of any
control system shall use the applicable EPA Reference Methods of 40 CFR Part
60, the most recent EPA test methods, or EPA-approved state methods, to
determine the efficiency of the control device; and
(d) meet the applicable recordkeeping
requirements for any control device.
(3) Any person may apply to the director for
approval of an alternate method of control. The application shall include a
demonstration that the proposed alternate produces an equal air quality benefit
as required by Subsection R307-316-4(1) or that meets Best Available Control
Technology thresholds.