Utah Admin. Code R315-264-1085 - Standards: Surface Impoundments
(a) The
provisions of Section R315-264-1085 apply to the control of air pollutant
emissions from surface impoundments for which Subsection
R315-264-1082(b)
references the use of Section R315-264-1085 for such air emission control.
(b) The owner or operator shall
control air pollutant emissions from the surface impoundment by installing and
operating either of the following:
(1) A
floating membrane cover in accordance with the provisions specified in
Subsection R315-264-1085(c); or
(2) A cover that is vented through a
closed-vent system to a control device in accordance with the provisions
specified in Subsection R315-264-1085(d).
(c) The owner or operator who controls air
pollutant emissions from a surface impoundment using a floating membrane cover
shall meet the requirements specified in Subsections R315-264-1085(c)(1)
through (c)(3).
(1) The surface impoundment
shall be equipped with a floating membrane cover designed to meet the following
specifications:
(i) The floating membrane
cover shall be designed to float on the liquid surface during normal operations
and form a continuous barrier over the entire surface area of the liquid.
(ii) The cover shall be fabricated
from a synthetic membrane material that is either:
(A) High density polyethylene (HDPE) with a
thickness no less than 2.5 millimeters; or
(B) A material or a composite of different
materials determined to have both organic permeability properties that are
equivalent to those of the material listed in Subsection
R315-264-1085(c)(1)(ii)(A) and chemical and physical properties that maintain
the material integrity for the intended service life of the material.
(iii) The cover shall
be installed in a manner such that there are no visible cracks, holes, gaps, or
other open spaces between cover section seams or between the interface of the
cover edge and its foundation mountings.
(iv) Except as provided for in Subsection
R315-264-1085(c)(1)(v), each opening in the floating membrane cover shall be
equipped with a closure device designed to operate such that when the closure
device is secured in the closed position there are no visible cracks, holes,
gaps, or other open spaces in the closure device or between the perimeter of
the cover opening and the closure device.
(v) The floating membrane cover may be
equipped with one or more emergency cover drains for removal of stormwater.
Each emergency cover drain shall be equipped with a slotted membrane fabric
cover that covers at least 90 percent of the area of the opening or a flexible
fabric sleeve seal.
(vi) The
closure devices shall be made of suitable materials that will minimize exposure
of the hazardous waste to the atmosphere, to the extent practical, and will
maintain the integrity of the closure devices throughout their intended service
life. Factors to be considered when selecting the materials of construction and
designing the cover and closure devices shall include: Organic vapor
permeability; the effects of any contact with the liquid and its vapor managed
in the surface impoundment; the effects of outdoor exposure to wind, moisture,
and sunlight; and the operating practices used for the surface impoundment on
which the floating membrane cover is installed.
(2) Whenever a hazardous waste is in the
surface impoundment, the floating membrane cover shall float on the liquid and
each closure device shall be secured in the closed position except as follows:
(i) Opening of closure devices or removal of
the cover is allowed at the following times:
(A) To provide access to the surface
impoundment for performing routine inspection, maintenance, or other activities
needed for normal operations. Examples of such activities include those times
when a worker needs to open a port to sample the liquid in the surface
impoundment, or when a worker needs to open a hatch to maintain or repair
equipment. Following completion of the activity, the owner or operator shall
promptly replace the cover and secure the closure device in the closed
position, as applicable.
(B) To
remove accumulated sludge or other residues from the bottom of surface
impoundment.
(ii)
Opening of a safety device, as defined in
40 CFR
265.1081, which is adopted by reference, is
allowed at any time conditions require doing so to avoid an unsafe condition.
(3) The owner or
operator shall inspect the floating membrane cover in accordance with the
following procedures:
(i) The floating
membrane cover and its closure devices shall be visually inspected by the owner
or operator to check for defects that could result in air pollutant emissions.
Defects include, but are not limited to, visible cracks, holes, or gaps in the
cover section seams or between the interface of the cover edge and its
foundation mountings; broken, cracked, or otherwise damaged seals or gaskets on
closure devices; and broken or missing hatches, access covers, caps, or other
closure devices.
(ii) The owner or
operator shall perform an initial inspection of the floating membrane cover and
its closure devices on or before the date that the surface impoundment becomes
subject to Section R315-264-1085. Thereafter, the owner or operator shall
perform the inspections at least once every year except for the special
conditions provided for in Subsection R315-264-1085(g).
(iii) In the event that a defect is detected,
the owner or operator shall repair the defect in accordance with the
requirements of Subsection R315-264-1085(f).
(iv) The owner or operator shall maintain a
record of the inspection in accordance with the requirements specified in
Subsection
R315-264-1089(c).
(d) The
owner or operator who controls air pollutant emissions from a surface
impoundment using a cover vented to a control device shall meet the
requirements specified in Subsections R315-264-1085(d)(1) through (d)(3).
(1) The surface impoundment shall be covered
by a cover and vented directly through a closed-vent system to a control device
in accordance with the following requirements:
(i) The cover and its closure devices shall
be designed to form a continuous barrier over the entire surface area of the
liquid in the surface impoundment.
(ii) Each opening in the cover not vented to
the control device shall be equipped with a closure device. If the pressure in
the vapor headspace underneath the cover is less than atmospheric pressure when
the control device is operating, the closure devices shall be designed to
operate such that when the closure device is secured in the closed position
there are no visible cracks, holes, gaps, or other open spaces in the closure
device or between the perimeter of the cover opening and the closure device. If
the pressure in the vapor headspace underneath the cover is equal to or greater
than atmospheric pressure when the control device is operating, the closure
device shall be designed to operate with no detectable organic emissions using
the procedure specified in Subsection
R315-264-1083(d).
(iii) The cover and its closure
devices shall be made of suitable materials that will minimize exposure of the
hazardous waste to the atmosphere, to the extent practical, and will maintain
the integrity of the cover and closure devices throughout their intended
service life. Factors to be considered when selecting the materials of
construction and designing the cover and closure devices shall include: Organic
vapor permeability; the effects of any contact with the liquid or its vapors
managed in the surface impoundment; the effects of outdoor exposure to wind,
moisture, and sunlight; and the operating practices used for the surface
impoundment on which the cover is installed.
(iv) The closed-vent system and control
device shall be designed and operated in accordance with the requirements of
Section
R315-264-1087.
(2) Whenever a
hazardous waste is in the surface impoundment, the cover shall be installed
with each closure device secured in the closed position and the vapor headspace
underneath the cover vented to the control device except as follows:
(i) Venting to the control device is not
required, and opening of closure devices or removal of the cover is allowed at
the following times:
(A) To provide access to
the surface impoundment for performing routine inspection, maintenance, or
other activities needed for normal operations. Examples of such activities
include those times when a worker needs to open a port to sample liquid in the
surface impoundment, or when a worker needs to open a hatch to maintain or
repair equipment. Following completion of the activity, the owner or operator
shall promptly secure the closure device in the closed position or reinstall
the cover, as applicable, to the surface impoundment.
(B) To remove accumulated sludge or other
residues from the bottom of the surface impoundment.
(ii) Opening of a safety device, as defined
in
40 CFR
265.1081, which is adopted by reference, is
allowed at any time conditions require doing so to avoid an unsafe condition.
(3) The owner or
operator shall inspect and monitor the air emission control equipment in
accordance with the following procedures:
(i)
The surface impoundment cover and its closure devices shall be visually
inspected by the owner or operator to check for defects that could result in
air pollutant emissions. Defects include, but are not limited to, visible
cracks, holes, or gaps in the cover section seams or between the interface of
the cover edge and its foundation mountings; broken, cracked, or otherwise
damaged seals or gaskets on closure devices; and broken or missing hatches,
access covers, caps, or other closure devices.
(ii) The closed-vent system and control
device shall be inspected and monitored by the owner or operator in accordance
with the procedures specified in Section
R315-264-1087.
(iii) The owner or operator shall
perform an initial inspection of the air emission control equipment on or
before the date that the surface impoundment becomes subject to Section
R315-264-1085. Thereafter, the owner or operator shall perform the inspections
at least once every year except for the special conditions provided for in
Subsection R315-264-1085(g).
(iv)
In the event that a defect is detected, the owner or operator shall repair the
defect in accordance with the requirements of Subsection R315-264-1085(f).
(v) The owner or operator shall
maintain a record of the inspection in accordance with the requirements
specified in Subsection
R315-264-1089(c).
(e) The
owner or operator shall transfer hazardous waste to a surface impoundment
subject to Section R315-264-1085 in accordance with the following requirements:
(1) Transfer of hazardous waste, except as
provided in Subsection R315-264-1085(e)(2), to the surface impoundment from
another surface impoundment subject to Section R315-264-1085 or from a tank
subject to Section
R315-264-1084
shall be conducted using continuous hard-piping or another closed system that
does not allow exposure of the waste to the atmosphere. For the purpose of
complying with this provision, an individual drain system is considered to be a
closed system when it meets the requirements of Subsection
R307-214-2(29),
which incorporates 40 CFR part 63, subpart RR-National Emission Standards for
Individual Drain Systems.
(2) The
requirements of Subsection R315-264-1085(e)(1) do not apply when transferring a
hazardous waste to the surface impoundment under either of the following
conditions:
(i) The hazardous waste meets the
average VO concentration conditions specified in Subsection
R315-264-1082(c)(1)
at the point of waste origination.
(ii) The hazardous waste has been treated by
an organic destruction or removal process to meet the requirements in
Subsection
R315-264-1082(c)(2).
(iii) The hazardous waste meets
the requirements of Subsection
R315-264-1082(c)(4).
(f) The
owner or operator shall repair each defect detected during an inspection
performed in accordance with the requirements of Subsections
R315-264-1085(c)(3) or (d)(3) as follows:
(1)
The owner or operator shall make first efforts at repair of the defect no later
than 5 calendar days after detection and repair shall be completed as soon as
possible but no later than 45 calendar days after detection except as provided
in Subsection R315-264-1085(f)(2).
(2) Repair of a defect may be delayed beyond
45 calendar days if the owner or operator determines that repair of the defect
requires emptying or temporary removal from service of the surface impoundment
and no alternative capacity is available at the site to accept the hazardous
waste normally managed in the surface impoundment. In this case, the owner or
operator shall repair the defect the next time the process or unit that is
generating the hazardous waste managed in the surface impoundment stops
operation. Repair of the defect shall be completed before the process or unit
resumes operation.
(g)
Following the initial inspection and monitoring of the cover as required by the
applicable provisions of Sections
R315-264-1080
through 1090, subsequent inspection and monitoring may be performed at
intervals longer than 1 year in the case when inspecting or monitoring the
cover would expose a worker to dangerous, hazardous, or other unsafe
conditions. In this case, the owner or operator may designate the cover as an
"unsafe to inspect and monitor cover" and comply with all of the following
requirements:
(1) Prepare a written
explanation for the cover stating the reasons why the cover is unsafe to
visually inspect or to monitor, if required.
(2) Develop and implement a written plan and
schedule to inspect and monitor the cover using the procedures specified in the
applicable section of Sections
R315-264-1080
through 1090 as frequently as practicable during those times when a worker can
safely access the cover.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.