Utah Admin. Code R392-300-7 - Required Plumbing - Modern Camps
(1)
(a) The operator shall ensure that the
minimum number of plumbing fixtures are provided to each modern camp in a
service building according to Table 1.
(b) Where a camp is not used exclusively by
one gender, the number of fixtures shall be based on 50% of the total number of
occupants being male and 50% being female.
(2) Showers and sinks shall be provided with
hot and cold potable water.
(3) A s
ink shall be located either in the same room as each toilet, or immediately
adjacent to the service building.
(4) For any toilet room intended to be used
by males only, a urinal may be substituted for a toilet for up to half of the
required number of toilets as long as the urinal is installed in the same
location as the toilets.
(5) A
service building shall be located not less than 15 feet and not more than 300
feet from any living and camping space served, unless integrated into a
permanent building at a modern camp.
(6) Soap and toilet tissue in a suitable
dispenser, and a waste receptacle with a lid shall be provided in each service
building.
(7) Clean individual
disposable towels, or other alternate hand drying method approved by the local
health officer, shall be provided at each sink.
(8) The operator shall ensure that each
service building is maintained in a clean and sanitary condition.
|
TABLE 1 Required Minimum Plumbing Fixtures for Modern Camps |
|||
|
Plumbing Fixtures |
Ratio of Plumbing Fixtures for Number of Camp Occupants *or fraction thereof |
||
|
Males |
Females |
Both Genders |
|
|
Toilets |
1:40* |
1:25* |
-- |
|
Sinks |
1:35* |
1:35* |
-- |
|
Showers |
1:35* |
1:35* |
-- |
|
Drinking Fountains |
-- |
-- |
1:300 |
|
Service Sink |
-- |
-- |
1 per service building |
|
Potable Water Faucet |
-- |
-- |
1 per service building |
Notes