010-8 Wyo. Code R. §§ 8-46 - Backflow Prevention, Indirect Drain
(a) Except as
specified under Chapter 8, Section
46(b), a direct connection
may not exist between the sewage system and a drain originating from equipment
in which food, portable equipment, or utensils are placed.
(b) A warewashing machine may have a direct
connection between its waste outlet and a floor drain when the machine is
located within five (5) feet (1.5 m) of a trapped floor drain and the machine
outlet is connected to the inlet side of a properly vented floor drain
trap.
(c) Paragraph (a) of this
Section does not apply to floor drains that originate in refrigerated spaces
that are constructed as an integral part of the building.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.